Zip HydroTap BC 100 Series Installation And Operating Instructions Manual Download Page 10

Page 10 of 20

Zip Hydro Tap Installation and Operating Instructions - 81467 - April 2006

Cleaning

Do not use strong, corrosive, spray or abrasive cleaners. Clean with a soft cloth
or brush and mild soap and water.

Do not spray water over the tap as it may damage the low-voltage  electronics.

Undersink units must never be located near, or cleaned with water jets.

The Zip HydroTap notifies when filter replacement is due. The default setting is
6000 Ltrs, but this can be set in increments of 1000Ltr from 1000Ltr to
10000Ltrs. When a filter change is due, the Change Filter light will flash white
once a minute and remain so until reset. A filter status light is located between
the Red and Blue Lights on the tap head assembly.

Depending on local water quality conditions and usage, the filter may require
changing anywhere from 1000 Ltrs to 10000 Ltrs. You may also need to
replace the filter if you notice unpleasant odours or tastes.

Some water may drip from the filter head (socket) during replacement. Keep a
bucket and towel handy to catch drips and mop up any spills.

To change the Filter:

1. Scroll through the screen menu to “Filter Flush Off” this isolates the water

supply.

2. Relieve system pressure via the filter flush stop cock, a quick open and

close will do.

3. Grasp filter cartridge and twist right to left one quarter turn until it stops.

4. Ease cartridge downwards to detach it from the filter head (socket).

5. Do not tilt the cartridge as dirty water may spill from it if tilted.

6. Unpack replacement cartridge and write today’s date where shown on the

label.

7. Avoid touching the filter “O” rings and filter opening as this may cause

bacterial contamination of the cartridge.

8. Align cartridge tabs with the slots on the under-side of the filter head.

9. Slide cartridge upward into head and rotate left to right until it stops.

10. Locate the filter flush hose situated behind the filter cartridge and run to a

container ready for flushing. Open the flush hose tap lever. On the control
panel press adjust 

, this will start the water flushing the cartridge. Allow

at least 7.5 Ltrs of water to run through to activate the filter and then
press adjust 

to stop the flow.

11. Isolate the filter flush stop cock and re-fit behind the filter cartridge.

12. Wipe up any spills and dispose of spent filter cartridge and packaging

thoughtfully.

13. Scroll through the menu to “Litres Filtered”, press adjust 

to reset litre

counter. Then it asks “are you sure”. Press adjust 

again to lock in the

command. After approx 10 seconds it will default to the selected mode.

Replacing the Filter 

(filtered models only)

Warning: 

If the Zip HydroTap is switched off for a long period of time

(e.g. more than a weekend), run water through the chilled water outlet for
at least 5 minutes before consumption.

Summary of Contents for HydroTap BC 100 Series

Page 1: ...lled drinking water for kitchens and tea rooms Installation and Operating Instructions 81467 April 2006 This Installation Instruction covers the following HydroTap models BC series B series HT series...

Page 2: ...ommissioning 7 Font Installation procedure 8 Operating the Tap 9 Cleaning 10 Replacing the Filter 10 Pull out Font Template pages a b c d Setting the Energy Saver Timer 11 AuxillIiary Fan Attachment 1...

Page 3: ...gh usage applications this must be installed in the top half of the cupboard door as a matter of course An accessory exhaust fan kit is available and should be used to ensure adequate ventilation Make...

Page 4: ...ned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed Power supply 220 240 Volt AC for connection to the heater via a 10 amp G P O Installation...

Page 5: ...dy and fit the 6mm nut to the All Thread using the tube spanner supplied in the kit Check the Tap Head position before securing it tightly against the bench sink top NOTE 1 The tap assembly must not b...

Page 6: ...d connect it to the hot water outlet located on the top center right hand side of the undersink unit Use spring clamps provided Measure and trim the unmarked tube and connect it to the vent outlet loc...

Page 7: ...he water to 95 C maintaining it at that temperature for a short stabilization period Once stabilized the element will cycle On bring the water to boiling point and hold it there for a short period The...

Page 8: ...base is flush with the bench top NOTE The fixing nut above the drain elbow can be loosened to correctly position the direction of the elbow Ensure when the re positioning is complete the nut is re tig...

Page 9: ...illed water Pulling up the Blue lever allows the tap to operate in a no touch mode Water will flow from between 5 and 15 seconds This is user adjustable To reset return the handle to the Off position...

Page 10: ...e and twist right to left one quarter turn until it stops 4 Ease cartridge downwards to detach it from the filter head socket 5 Do not tilt the cartridge as dirty water may spill from it if tilted 6 U...

Page 11: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...

Page 12: ......

Page 13: ......

Page 14: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006...

Page 15: ...ed press Adjust button once and Are You Sure will be displayed Press Adjust once and Litres Filtered will be reset to 0 Activating Sleep Mode This mode allows the HydroTap to go into Energy Saving mod...

Page 16: ...th a safety mode that allows protection against accidental operation by Infirmed or disabled persons 1 On the LCD scroll through the menu to Hot Isolation 2 Press adjust to activate 3 Now go to the Ta...

Page 17: ...k power plug is correctly fitted and switch is turned on Check for loom connection Contact local Zip Service Provider Check LCD for information Check filter usage on LCD screen if filter change is dis...

Page 18: ...3 compressor kit BC150 175 7 90633 cold sensor probe kit blue 18 90639 fan motor kit BC100 125 8 90634 pump kit cold 18 90640 fan motor kit BC150 175 9 90622 PCB kit BC100 125 BC150 175 19 90437 capac...

Page 19: ...ed hose inlet 4 90616 gasket and elbow kit BC 100 125 16 90629 level sensor kit hot tank BC100 125 4 90617 gasket and elbow kit BC 150 175 16 90630 level sensor kit hot tank BC150 175 5 90579 overload...

Page 20: ...gle Solenoid Kit 4 90658 Gasket and Elbow Kit BC 100 125 5 90579 Overload Kit 6 90618 Element 1500 watt Kit 7 90620 Sensor Probe Hot 8 90621 Pump Kit Hot 9 90689 PCB Kit Boiling Only 10 90624 Leak Sen...

Page 21: ...Pump Kit Hot 9 90660 PCB Kit Boiling Only 10 90624 Leak Sensor Kit 11 90625 Control Panel Kit 12 90130 Clips Kit 13 90628 Stop Valve and John Guess Fittings Kit 14 90056 Flexible Inlet Hose Kit 15 90...

Page 22: ...Page 18 of 20 Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Notes...

Page 23: ...Zip Hydro Tap Installation and Operating Instructions 81467 April 2006 Page 19 of 20 Notes...

Page 24: ...nd the rate of water consumption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted...

Reviews: