Zip HydroTap Installation and Operating Instructions - 82872 - July 2003

Step D - Connecting the water supply (all models)

To prevent sediment from entering the Zip HydroTap at connection, flush
water through the supply thoroughly before connection to the HydroTap.

Open the access door and check that the filter is in place and secure.

Connect water supply to undersink unit using flexible hose already
attached.

Step E - Testing and commissioning

Check that all installation steps have been carried out correctly

Locate the red fill switch on the upper left-hand side of the undersink unit
and check that it is in the Fill (Up) position.

Connect the undersink unit to the power and turn the power and water on.
Check that the tap-head lamps operate according to the model as follows:

Models ABC and ABB: All three lamps on

Model ABA: Lamps 1 and 3 on, lamp 2 off

Model B: Lamps 1 and 2 on, lamp 3 off

The boiling water tank is now filling and after a short time, water will start
to flow from the tap. Allow the water to flow for five minutes to charge the
filter and ensure clean clear water. Allow sufficient water to flow through
the filter to clear the water of carbon fines.

Set the Fill switch to the On (down) position. The water will stop flowing.

For Model ABC, press and hold the blue button for about 1 minute after
water begins to flow.

Check that the lamps operate according to the model as follows:

Model ABC: Lamps 1 and 2 flash once per second and lamp 3 flashes once
per minute

Model ABA: Lamp 1 flashes once per second, and lamp 3 flashes once per
minute.

Model ABB: Lamp 1 flashes once per second, lamp 2 stays on, and lamp 3
flashes once per minute.

Model B: Lamp 1 flashes once per second and lamp 2 stays on.

Check all connections for water leaks, rectify as necessary.

Write the date on the filter cartridge (all models except model B).

After approximately 15 minutes, lamps which were flashing (lamps 1 and/or
2) will stop flashing and stay on to indicate that the water has reached the
correct temperature. Lamp 3 will continue to flash once per minute.

Test Water delivery from the tap checking for appropriate temperatures.

Use cable clips to tidy and secure wiring.

If required for Model ABC, set up the energy saver timer as detailed on page 13.

Installation procedure continued

Water connection

Stop
cock

Flexible
hose

Fill switch location

Tap head lamps

Lamp 3

Lamp 2

Lamp 1

Chilled (Model ABC) or ambient 
(Model ABA) water button

Boiling water
button

On models ABB and B
both buttons dispense
boiling water

Electrical Connection

Cold Supply

Hot outlet

Vent

Summary of Contents for HydroTap ABA10FXC

Page 1: ...s 73078 Zip HydroTap ABC10 30FXC 73119 Zip HydroTap ABC30 30FXC 73081 Zip HydroTap ABA10FXC 73123 Zip HydroTap ABA30FXC 73118 Zip HydroTap ABB10FXC 73121 Zip HydroTap ABB30FXC 73110 Zip HydroTap B1OC 73111 Zip HydroTap B3OC Installation Instructions and Operating Procedures ...

Page 2: ...Page 2 of 20 Zip HydroTap Installation and Operating Instructions 82872 July 2003 ...

Page 3: ...alling the undersink unit all models 7 Step C Connecting the tap 7 Installation with Tap Font 8 Tap Font Mounting Template a d Installation procedure Continued 13 Step C Connecting The Tap continued 13 Step D Connecting the water supply all models 14 Step E Testing and commissioning 14 Solving general problems 15 Operating the Tap 16 Cleaning 17 Replacing the Filter 17 Setting the Energy Saver Tim...

Page 4: ...the Zip HydroTap undersink unit Some units may exceed safe lifting limits Do not lift without assistance The weights of the units are given in the table under Installation Requirements page 5 Airflow Proper air circulation must be provided The system will operate satisfactorily only if the recommended air gaps are provided If this is not possible ventilation slots must be cut into the top AND bott...

Page 5: ...oned so that the connection point and the stop cock will not be obstructed when the undersink unit is installed A water supply which can deliver 2 litres per minute flow rate at minimum of 1 5 Bar 150 kPa flow dynamic pressure Power supply connection to the heater via a double pole fused spur with a minimum break rating of 13 amps Cold water supply with a minimum working pressure of 1 5 bar 150 kP...

Page 6: ... that the tap will be able to drain into the sink Mark the two hole centres and cut the small hole using a 13 5 mm sheet metal hole punch Cut the large hole using a 35 mm sheet metal hole punch Install the tap making sure it is adequately sealed To ensure proper sealing make sure that the tap mounting items are assembled in the order shown in the Assembly Detail diagram below Ensure that the upper...

Page 7: ...D bottom of the cupboard door Make sure that ventilation grilles are not obstructed Allow access to water inlet located on the left hand side of undersink unit Step C Connecting the tap Model ABC Mount the External Chilled Water Expansion Chamber ECWEC into the cold water outlet on the top of the undersink unit by pressing down firmly into the John Guest fitting Measure and trim the blue tube and ...

Page 8: ...o pedestal is positioned above largest hole in bench Pass all cables and tubes from pedestal through largest hole in bench Fit clamp spacer and lock nut on to drain bush and tighten securely Clean off any sealant squeezed out around sump tray during clamping Connecting Install the waste clamp in an accessible position on the sink side of drain trap and as high as possible above the trap water line...

Page 9: ...Zip HydroTap Installation and Operating Instructions 82872 July 2003 Page a Detach this papertemplate and use it to position your Zip Hydrotap Tap Font on your kitchen bench ...

Page 10: ...80 mm 45 mm MINIMUM CLEARANCE FROM REAR WALL CIRCUMFERENCE OF TAP FONT BASE SMALL HOLE SCREW HOLE SCREW HOLE ...

Page 11: ...57 mm SCREW HOLE SCREW HOLE LARGE HOLE ...

Page 12: ...Page d Zip HydroTap Installation and Operating Instructions 82872 July 2003 Detach this paper template and use it to position your Zip Hydrotap Tap Font on your kitchen bench ...

Page 13: ...ngs vertically Model B Measure and trim the red marked tube and connect it to the hot water outlet on the top of the undersink unit Measure and trim the unmarked tube and connect it to the vent outlet on the top of the undersink unit Connect the tap electrical connector to the cord attached to the undersink unit Align the pins carefully and do not force the plug Clamp the cable to the wall with cl...

Page 14: ...t the Fill switch to the On down position The water will stop flowing For Model ABC press and hold the blue button for about 1 minute after water begins to flow Check that the lamps operate according to the model as follows Model ABC Lamps 1 and 2 flash once per second and lamp 3 flashes once per minute Model ABA Lamp 1 flashes once per second and lamp 3 flashes once per minute Model ABB Lamp 1 fl...

Page 15: ... provider The red lamp flashes once a second There is a problem with the Turn off the power and the water when the water is hot undersink unit and call your Zip service provider The boiling water is running The Fill switch is in the wrong Move the Fill switch on the left o continuously position Up side of the unit to the down position The boiling water is not dispensing The Tap safety lock is set ...

Page 16: ...is a leak in the undersink water system and the unit will be shut down In this case call Zip services Filter Change Light Flashing slowly once every minute The light will flash once every minute when the filter is within its specified lifespan Flashing rapidly once per second The light will flash once per second when the filter is due for replacement Refer to section 3 Replacing the filter Boiling...

Page 17: ...ach it from the filter head socket 4 Do not tilt the cartridge as dirty water may spill from it if tilted 5 Unpack replacement cartridge and write today s date where shown on the label 6 Avoid bacterially contaminating cartridge top whilst inserting into head 7 Align cartridge tabs with the slots on the under side of the filter head 8 Slide cartridge upward into head and rotate left to right until...

Page 18: ... selected Press and release button m until correct minute is selected When day hour and minute are correct release button Programming Power ON OFF 1 Press and release the Prog button once 2 Display will show first setting 1 ON 3 Triangle over 1 indicates setting for Monday 4 Press and release h and m buttons to set ON time 5 Press and release the Prog button once 6 Display will show second setting...

Page 19: ...e returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary according to water quality and the rate of water consumption Zip does not exclude restr...

Page 20: ...egistered trade marks Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US5103859 and US5099825 Other patents are in force and patent applications are pending Zip Heaters UK Ltd 14 15 Bertie Ward Way Rash s Green Dereham Norfolk NR19 1TE www zipheaters co uk Telephone 0870 608 8888 Facsimi...

Reviews: