Zip HydroTap 3-in-1 Installation And Operating Instructions Manual Download Page 7

Page 7 of 24 

                                   

HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1.05

These Installation Instructions cover the 3-in-1 and 4-in-1HydroTap range. Use 
the chart on the left to identify the model you are using:

Commercial  Models: 

BCH   =  Boiling / Chilled and Hot / Cold. Standard Tap  (4-in-1) 
BCHT  =  Boiling / Chilled and Hot / Cold. Tall Mixer Tap (4-in-1)
BCHS  =  Boiling / Chilled and Hot / Cold. Square Mixer Tap (4-in-1)
BH  F  =  Boiling and Hot / Cold. Standard Tap (3-in-1)
BHT F = Boiling and Hot / Cold. Tall Mixer Tap (3-in-1)
BHS F = Boiling and Hot / Cold. Square Mixer Tap (3-in-1

Boiling Water Capacity:

160 = 160 cups in one hour** 200 = 200 cups in one hour**

** Capacity will be reduced by the volume of water used when operating the mixer tap.

Chilled  Water Capacity: (BCH only)

125 = 125 glasses in one hour   175 = 175 glasses in one hour

Note: 

The 

Cup

 measurement = 167mls, the 

Glass 

measurement = 200mls.

+ signifies models are ‘freeflow’ ensuring cold water continues to flow when 
chilled glasses per hour is exceeded during periods of high demand.

Installation Requirements

Before installing ensure that the following have been provided at the installation site:

•  Sufficient space in the cupboard to install the undersink unit in accordance with these Installation Instructions. 

 

A table of dimensions is given above.

NOTE: Add 65mm to the Depth of the undersink unit to allow for Water and Electrical connections. 

•  A potable mains water supply connection with isolating valve inside the cupboard within reach of the 750mm flexible 

connection and positioned so that the connection point and the stop cock will not be obstructed when the undersink 
unit is installed.

•  Power supply 220-240 Volt AC, for connection to the unit via a 13 amp fused spur.

•  This switch must provide all-pole disconnection and a contact separation of at least 3mm installed in accordance with 

wiring rules.

Specifications

Model

Max. 

Boiling 

Cups/hr

Max. 

Chilled 

Glasses/hr

Width 

mm

Depth 

mm

Height 

mm

Weight 

empty  

kg’s

Weight 

full 

kg’s

Power 

Rating 

kW @ 

230V

BH160F 
BHT160F 
BHS160F

(Standard Tap)

(Tall Tap)

(Square Tap)

160

-

333

323

353

9.5

12.0

2.1

BH200F 
BHT200F 
BHS200F

(Standard Tap)

(Tall Tap)

(Square Tap)

200

-

364

340

409

10.0

14.0

2.6

BCH160/125+      
BCHT160/125+    
BCHS160/125+   

(Standard Tap)

(Tall Tap)

(Square Tap)

160

125

440

473

337

28.0

35.0

2.3

BCH200/175+ 
BCHT200/175+ 
BCHS200/175+

(Standard Tap)

(Tall Tap)

(Square Tap)

200

175

500

508

395

29.5

38.0

2.8

BCH 160 125

Model

Cups of 

Boiling 

Water 

per Hour

Glasses 

of Chilled 

Water 

per Hour

Summary of Contents for HydroTap 3-in-1

Page 1: ...ydroTap 4 in 1 and Zip HydroTap 3 in 1 Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction cover...

Page 2: ...HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05...

Page 3: ...the under counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all...

Page 4: ...d BC assemblies which have been factory modified to accept a secondary mixer tap The mixer tap is connected so that it draws water directly from the cold water mains as well as from the boiling water...

Page 5: ...responsibility to supply if necessary and install all valves as required by local regulations and relevant standards The plumbing installation must be done in accordance with local Water Authority re...

Page 6: ...unit is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature This unit must not be positioned in an area that may be cleaned by a water jet and mus...

Page 7: ...ation site Sufficient space in the cupboard to install the undersink unit in accordance with these Installation Instructions A table of dimensions is given above NOTE Add 65mm to the Depth of the unde...

Page 8: ...nut to the All Thread using the tube spanner supplied in the kit Check the Tap Head position before securing it tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more...

Page 9: ...he undersink unit SPECIAL NOTE The HydroTap undersink units are heavy take note of the weights listed in the table on page 7 If you think you cannot lift the unit safely get help and avoid possible in...

Page 10: ...ny excess or allow kinking of the tubes When connecting slide the tube over the pipe at least 25mm There are black plastic clamps provided on the boiling and chilled hoses to choke the flow if require...

Page 11: ...responds to the direction indicated by the arrow on the filter head and by the instructions listed on the rear panel of the under sink unit Check the lower left hand John Guest fitting is the Inlet fr...

Page 12: ...and exit model description selection setting 4 The model selection is now complete The Start Filt Flush will be displayed Fig d Start Filt Flush Press Adjust Fig d Scroll Exit BC160 125 Press ADJUST o...

Page 13: ...nce to return to the service default screen To change the service default screen back to Normal Operation press the adjust buttons together until the screen changes back Warning Caution must be observ...

Page 14: ...n trap spigot available If a spigot is not available use the snap on spigot and worm drive clamps supplied in the kit Instructions and diagrams are supplied in the kit 8 Ensure the positioning of the...

Page 15: ...to be manually returned to the Off position Chilled Water Lever Depressing the Blue lever allows dispensing of Chilled water Pulling up the Blue lever allows the tap to operate in a no touch mode Wate...

Page 16: ...ox 10 seconds it will default to the selected mode The Zip HydroTap notifies when filter replacement is due The default setting is 6000 litres but this can be set in increments of 1000 litres from 100...

Page 17: ...touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 9 Align cartridge tabs with the slots on the under side of the filter head 10 Slide cartridge...

Page 18: ...once and Monday Off will be displayed Now press Adjust until required time is reached If each individual day is to have an On Off time these steps need to be repeated for each day and for each On Off...

Page 19: ...enu and selecting de activate when Hot isolation Mode is displayed on the screen 7 The LCD will show Normal Operation Set The Boiling Chilled Water Dispensing Times The ability to change the maximum d...

Page 20: ...Boiling water to any one sink or may be fitted with a Font kit when a sink is not available The Font must be connected to a suitable drain NOTE The Venturi connection for the 4 in 1 Mixer tap is locat...

Page 21: ...lves 1 2 Page 22 Faulty restrictaflow valve Clean and reset restrictaflow valve item 3 Page 22 Water supply not connected Check plumbing connection turn water ON No hot water from mixer Hot tank empty...

Page 22: ...ion and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05 Page 22 of 24 Trouble Shooting Continued 1 2 3 Item Description Part No 1 Chec Valve 15mm SP88508 2 Check Valve 8mm SP8850...

Page 23: ...Page 23 of 24 HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05 Notes...

Page 24: ...s incurred by a Zip Service Provider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty...

Reviews: