Read These Warnings First

Zip Hydrotap undersink assembly.

The appliance must be placed in a horizontal,  

upright position, as shown above.

BCH Unit

BH Unit

Note:

Always ensure the tubes are 

shortened so that any excess 

is removed and their route is 

the most direct line between 

the tap assembly and the 

HydroTap unit.

Do not allow the tubes to sag 

or droop so water is trapped 

within the hoses. Always 

maintain a constant fall

Positioning of the tap assembly 

must be within the following 

parameters:

The height between the base of 

the Hydrotap unit and the base 

of the Tap assembly cannot be 

greater than 900mm.

Safety

This appliance is not intended for use by persons (including children) with reduced 
physical sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. Children should be supervised to ensure that they 
do not play with the appliance.

Refrigerant

The Zip HydroTap Chilling unit contains 134a refrigerant under pressure. No part 
of the unit should be exposed to a naked flame. Maintenance of the refrigeration 
unit must be carried out by an accredited service provider or qualified refrigeration 
mechanic.

Qualifications

If the power cable is damaged it must be repaired only by a qualified technician. To 
avoid hazards, all installation procedures must be carried out by a suitably qualified 
tradesperson. The power cable and power outlet must be in a safe visible position for 
connection.
The power supply cable must be adequately secured. 
Do not remove the cover of the appliance under any circumstances without first 
isolating the appliance from the power supply. 
As the installer, it is your responsibility to supply (if necessary) and install all valves as 
required by local regulations and relevant standards.
The plumbing installation must be done in accordance with local Water Authority 
regulations and these Installation Instructions. 

 This appliance must be earthed.

Venting

Sometimes steam and / or boiling water may discharge through a vent outlet at the 
mouth of the tap. If the tap is not installed using the Font pedestal, ensure the tap 
body is located so the tap outlet safely drains into the sink bowl area. 

NOTE:

 On startup, the controls take the system through a calibration process which 

causes the unit to over-boil for a period of 90 seconds. Once this mode is completed 
the system reverts back to normal operation.

Lifting

Take care when lifting the Zip HydroTap undersink unit. Some units may exceed safe 
lifting guidelines. If you feel this is beyond your personal capabilities, please seek 
assistance with the lift. The weights of the units are marked on the packaging and are 
given in the table on page 7. Do not lift the unit by the doors. 

Airflow

The ambient temperatures this unit should operate within are 5ºC - 35ºC.  
Proper air circulation must be provided. The system will operate satisfactorily only 
if the recommended air gaps are provided, these are 65mm min rear clearance 
and 50mm side clearance. An air vent is provided with each unit for high usage 
applications, this must be installed in the top half of the cupboard door as a matter of 
course. An accessory exhaust fan kit is available and when supplied should always 
be fitted to ensure adequate ventilation. Make sure that the ventilation grilles of the 
undersink unit are not obstructed. 

I

ncluded in the installation pack are adhesive 

backed silicon buffers. If air vents are not installed in the cupboards housing the 
HydroTap, the buffers must be placed on the inside edge of the cupboard door to 
create a slight gap  ensuring a minimum airflow. Failure to do this may cause the 
HydroTap to overheat and operate inefficiently.

Front View

Side View

Side View

Front View

Summary of Contents for HydroTap 3-in-1

Page 1: ...ydroTap 4 in 1 and Zip HydroTap 3 in 1 Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction cover...

Page 2: ...HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05...

Page 3: ...the under counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all...

Page 4: ...d BC assemblies which have been factory modified to accept a secondary mixer tap The mixer tap is connected so that it draws water directly from the cold water mains as well as from the boiling water...

Page 5: ...responsibility to supply if necessary and install all valves as required by local regulations and relevant standards The plumbing installation must be done in accordance with local Water Authority re...

Page 6: ...unit is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature This unit must not be positioned in an area that may be cleaned by a water jet and mus...

Page 7: ...ation site Sufficient space in the cupboard to install the undersink unit in accordance with these Installation Instructions A table of dimensions is given above NOTE Add 65mm to the Depth of the unde...

Page 8: ...nut to the All Thread using the tube spanner supplied in the kit Check the Tap Head position before securing it tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more...

Page 9: ...he undersink unit SPECIAL NOTE The HydroTap undersink units are heavy take note of the weights listed in the table on page 7 If you think you cannot lift the unit safely get help and avoid possible in...

Page 10: ...ny excess or allow kinking of the tubes When connecting slide the tube over the pipe at least 25mm There are black plastic clamps provided on the boiling and chilled hoses to choke the flow if require...

Page 11: ...responds to the direction indicated by the arrow on the filter head and by the instructions listed on the rear panel of the under sink unit Check the lower left hand John Guest fitting is the Inlet fr...

Page 12: ...and exit model description selection setting 4 The model selection is now complete The Start Filt Flush will be displayed Fig d Start Filt Flush Press Adjust Fig d Scroll Exit BC160 125 Press ADJUST o...

Page 13: ...nce to return to the service default screen To change the service default screen back to Normal Operation press the adjust buttons together until the screen changes back Warning Caution must be observ...

Page 14: ...n trap spigot available If a spigot is not available use the snap on spigot and worm drive clamps supplied in the kit Instructions and diagrams are supplied in the kit 8 Ensure the positioning of the...

Page 15: ...to be manually returned to the Off position Chilled Water Lever Depressing the Blue lever allows dispensing of Chilled water Pulling up the Blue lever allows the tap to operate in a no touch mode Wate...

Page 16: ...ox 10 seconds it will default to the selected mode The Zip HydroTap notifies when filter replacement is due The default setting is 6000 litres but this can be set in increments of 1000 litres from 100...

Page 17: ...touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 9 Align cartridge tabs with the slots on the under side of the filter head 10 Slide cartridge...

Page 18: ...once and Monday Off will be displayed Now press Adjust until required time is reached If each individual day is to have an On Off time these steps need to be repeated for each day and for each On Off...

Page 19: ...enu and selecting de activate when Hot isolation Mode is displayed on the screen 7 The LCD will show Normal Operation Set The Boiling Chilled Water Dispensing Times The ability to change the maximum d...

Page 20: ...Boiling water to any one sink or may be fitted with a Font kit when a sink is not available The Font must be connected to a suitable drain NOTE The Venturi connection for the 4 in 1 Mixer tap is locat...

Page 21: ...lves 1 2 Page 22 Faulty restrictaflow valve Clean and reset restrictaflow valve item 3 Page 22 Water supply not connected Check plumbing connection turn water ON No hot water from mixer Hot tank empty...

Page 22: ...ion and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05 Page 22 of 24 Trouble Shooting Continued 1 2 3 Item Description Part No 1 Chec Valve 15mm SP88508 2 Check Valve 8mm SP8850...

Page 23: ...Page 23 of 24 HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05 Notes...

Page 24: ...s incurred by a Zip Service Provider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty...

Reviews: