background image

13

Installation instructions & user manual 
806310UK  V1.00 July 2019 - HydroChill HC05

Technical support  

Tel: 0345 6 005 005  Email: [email protected]  www.zipwater.co.uk

Insert filter

Rotate

Insert

Filter replacement

Remove filter

Rotate

Pull

•  For safe operation, the filter cartridge should be replaced at least every 6 months, 

or earlier if you notice a persistent reduction in water pressure from the tap or an 
unpleasant taste or odour in the water.

•  For safe operation, thoroughly flush the water through after periods of non-use 

longer than 12 hours.

•  Not changing the filter cartridges when required may cause the water to become 

biologically unsafe.

•  Use only a Zip filter to match the one used in your chiller product (see Spare parts 

page 5). The filter cartridge can be obtained directly from Zip, visit www. zipwater.
co.uk or alternatively call Zip on 0345 6 005 005.  
The filter is located behind the front access panel on the HydroChill. The installation 
date should be written on the filter cartridge. No special tools or skills are required 
to install the filter cartridge.

•  Disconnect the mains  electricity supply.
•  Unscrew the front panel (2 screws at bottom of panel) & lift out to locate the filter.
•  Grasp the filter cartridge firmly and twist it horizontally a quarter turn clockwise until 

it stops. 
Some water will drip from the filter head during the replacement process so it is a 
good idea to have a bucket and cloth handy to catch and mop up any spills.

•  Ensure that the electrical connections do not get wet.
•  Gently ease the cartridge downwards to detach it from the filter head, then pull it out 

and discard responsibly. Take care not to tip it up once free as water may spill out.

•  Write the date of replacement on the new filter cartridge label. 
•  Remove the protective plastic cap. Insertion method is opposite to removal.
•  Align the tabs of the replacement cartridge with the filter head and insert it up into 

the filter head.

•  Turn the replacement cartridge a quarter turn anti-clockwise until it stops and locks 

into position. 

•  When the filter replacement has been completed, purge the system of trapped air by 

dispense water from the tap until it flows without any further spluttering. Run 10 litres 
of water through the system to complete the purge.

•  Refit the front panel, clean the stainless steel surfaces, wipe dry any water spills.
•  Reconnect  the mains electricity supply, & wait for the water to cool before drinking.

!

!

Summary of Contents for HydroChill HC05T128

Page 1: ...rmanual 806310UK V1 00July2019 HydroChillHC05 Technicalsupport Tel 03456005005 Email service zipindustries co uk www zipwater co uk Installation instructions usermanual Zip HydroChill HC05Floorstandin...

Page 2: ...stem Installation This system must be installed in accordance with water supply byelaws current IEE regulations and relevant local authority byelaws Electrical o The appliance must be connected to the...

Page 3: ...equired for an extended period of time 48 hours or more do not fill and commission it until ready for first use The HydroChill must be sanitised during the commission process please contact the Zip Wa...

Page 4: ...er pressure of 0 15 MPa 1 5 bar If the incoming mains cold water supply pressure exceeds 0 7 MPa 7 0 bar a pressure reducing valve is required to be fitted in the supply line See Accessories page 6 Wa...

Page 5: ...Motor Kit 8 95132 Relay Compressor AE4430Y GS1A 50 60 9 95133 Capacitor Compressor Tecumseh AE4430Y GS1A 10 95134 Overload Compressor Tecumseh AE4430Y GS1A 11 94441 Compressor Tecumseh AE4430Y GS1A 1...

Page 6: ...lowing have been provided at the installation site Review of all the technical specifications Ensure the floor can support the product weight when full of water allow an extra 4kg when full For Zip Hy...

Page 7: ...ater that can flow through at one time is limited to a pre determined maximum providing the flow rate through it exceeds 2 litres per minute The Water Block also incorporates a non return valve The Wa...

Page 8: ...correct and that the filter screen see Fig 2 is inserted correctly with the convex surface facing towards the water supply 1 2 Installation Fig 2 Fit key to adjust flow Key Reset lever 1 3 Reset Proce...

Page 9: ...5005 Email service zipindustries co uk www zipwater co uk Installation Section 2 Ventilation 50mm back clearance 50mm RHS side clearance 300mm LHS side clearance 400mm 2 0 Clearance envelope For safe...

Page 10: ...t unscrew the grub screw at the back of the tap base in order that it does not foul the o rings bearing on the tap spout Lubricate the o rings on the tap spout with water Align spout base carefully pr...

Page 11: ...t supplied Isolation valves are not supplied 4 1 Connect the water supply and waste pipe 4 1 Connect the water supply and waste pipe It is the installer s responsibility to ensure the installation com...

Page 12: ...s for leaks Repair as necessary again turn the incoming mains cold water supply on re purge and then turn on the mains electricity supply The chiller unit takes up to 20 minutes to chill it s contents...

Page 13: ...upply Unscrew the front panel 2 screws at bottom of panel lift out to locate the filter Grasp the filter cartridge firmly and twist it horizontally a quarter turn clockwise until it stops Some water w...

Page 14: ...Note Factory Setting is 6 months TIME MONTHS SWITCH 1 SWITCH 2 SWITCH 3 SWITCH 4 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF TEST X X X ON X Any...

Page 15: ...nt diagram Remove the panel and clean the condenser using a soft bristled brush or vacuum Replace the panel and restore power when complete Leak Detector A Leak Detector is built into the appliance If...

Page 16: ...onnected or turned on Connect or turn on water supply Water pressure regulator failed Contact local Zip Service Provider Unit frozen up Contact local Zip Service Provider Internal water leak Contact l...

Page 17: ...ranty does not apply to any consumables Consequently no warranty applies to the life of any filtration cartridge installed within the appliance as cartridge life may vary according to water quality an...

Page 18: ...18 Installationinstructions usermanual 806310UK V1 00July2019 HydroChillHC05 Technical support Tel 03456005005 Email service zipindustries co uk www zipwater co uk Notes...

Page 19: ...19 Installationinstructions usermanual 806310UK V1 00July2019 HydroChillHC05 Technicalsupport Tel 03456005005 Email service zipindustries co uk www zipwater co uk Notes...

Page 20: ...instructions usermanual 806310UK V1 00July2019 HydroChillHC05 Technical support Tel 03456005005 Email service zipindustries co uk www zipwater co uk ZipWaterUK 03456005005sales zipindustries co uk www...

Reviews: