Installation instructions & user manual
804546UK V2.06 Oct 2018 - Zip Hydroboil Plus
Technical support
Tel: 0345 6 005 005 Email: [email protected] www.zipwater.co.uk
!
!
Before installation
Before installation ensure that provision has been made for the
following
•
Review the technical specifications.
•
Ensure the mounting wall can support the product weight when full of water
(See Technical specification, page 6).
•
Provide sufficient space to install the Hydroboil Plus and other components in
accordance with these installation instructions.
• Position the Hydroboil Plus so there is at least 150 mm clearance above it
for service access, 65 mm to its left and 20 mm to its right – the tap nozzle is
usually positioned nominally 360 mm above a draining board, drip tray or sink
bowl area.
•
For all Zip Hydroboil Plus models, user easy accessible 1 x 230V AC 13A socket or
double pole isolation switch, (correctly rated for the appliance), is required.
•
The Hydroboil Plus must be connected in accordance with IEE regulations. See
Technical specification, page 6 for power ratings.
Note
Check cable and plumbing against inlet /outlet positions before proceeding.
•
A wholesome (cat 1) water supply connection with isolating valve within
reach of the Hydroboil Plus (and positioned so that the stop cock will not be
obstructed when the Hydroboil Plus is installed).
• Vent / outlet drainage to a draining board, drip tray or sink bowl area.
• Access to drainage from a vent situated at the base of the Hydroboil Plus.
•
A wholesome (cat 1) cold water supply with a minimum working pressure of:
(see Technical specification, page 6 min. / max. water supply pressure).
•
A 0.35 MPa (3.5 bar) pressure limiting valve supplied must be fitted if the
incoming mains water pressure is likely to exceed 0.5 MPa (5.0 bar).
•
The Hydroboil Plus must be placed with its base in a horizontal position.
IMPORTANT!
Do not proceed with the installation if these requirements are not
met.