Zip Hydroboil HS010 Installation And Operating Instructions Manual Download Page 4

29.5 kgs

10 litre models

Page 4 of 12

Zip Hydroboil - Installation & Operating Instructions - 81447 - February 2004

This switch must provide all-pole disconnection and a contact seperation of
at least 3 mm installed in accordance with wiring rules.

c) Cold water supply with a minimum working pressure of 10 bar and a

maximum working pressure of 7 bar connected via an isolation valve.

d) Outlet drainage to a sink draining board or to a drip tray.

e) Access to drainage from a vent situated at the base of the heater.

f)

In all installation instances the walls of the heater must be vertical and the
base horizontal, there can be no exceptions to this rule.

Note:

If the water pressure is likely to exceed 7 bar, a 3.5 bar pressure

reducing valve must be installed in the cold water supply line.

Before you begin

Locate the paper mounting-hole template packed with the heater.

Read the installation and operating instructions completely.

Decide whether to install with concealed or exposed plumbing and / or
electrical connections. Concealed connections are preferred for a superior
appearance.

If the heater is used for filling cups, then insert the flow restrictor into the outlet
pipe before securing tap assembly.

Step 1 - Positioning

Position the heater so the tap will drain onto the draining board or drip tray.

Position the base of the tap to be not less than 200 mm above the draining
board. ( height should be increased only if it is essential to accommodate larger
vessels.)

Minimum clearances for service are 150 mm top, 65 mm left and 20 mm right.

Mark corner position on wall so to position mounting-hole template.

Step 2 - Fastening

Position mounting-hole template on the wall and drill mounting holes where
shown.

Drill holes for water inlet, vent outlet and wiring if it is intended to install the
heater with concealed electrical and plumbing connections.

Remove cover fastening screws and lift cover away from chassis.

Installation Procedures

15 litre models

34.5 kgs

25 litre models

47 kgs

40 litre models

71 kgs

Installation Requirements 

continued

Approximate Weights When Filled

Summary of Contents for Hydroboil HS010

Page 1: ...51 Hydroboil 10 Litre Stainless Steel HS110 11552 Hydroboil 15 Litre White HS015 11551 Hydroboil 15 Litre Stainless Steel HS115 12552 Hydroboil 25 Litre White HS025 12551 Hydroboil 25 Litre Stainless...

Page 2: ...uirements 3 Installation Procedures 4 Step 1 Positioning 4 Step 2 Fastening 4 Step 3 Connecting 5 a Plumbing 5 b Venting 5 c Electrical 6 Step 4 Assembling 6 Step 5 Commissioning 6 Problem Solving 7 O...

Page 3: ...ian Do not remove the cover of the heater under any circumstances without first isolating the heater from the power supply Do not use strong corrosive or abrasive cleaners to clean the case of the hea...

Page 4: ...er to install with concealed or exposed plumbing and or electrical connections Concealed connections are preferred for a superior appearance If the heater is used for filling cups then insert the flow...

Page 5: ...with a isolating valve which allows it to be isolated from the mains supply for servicing Water pressure requirements Minimum 0 1 bar Maximum 7 bar Warning If pressure is likely to exceed 7 bar a pres...

Page 6: ...crew the tap clockwise until the tap assembly touches the fascia without pressure Continue to turn the tap a further one full turn until the tap lever is upright Step 5 Commissioning Check previous st...

Page 7: ...s a vessel to be filled without holding your hand where it may be affected by steam Pot fill position Cup fill position Symptom Possible Cause Solution Fails to dispense water Water isolating valve tu...

Page 8: ...d during that period the text Boiling Water may not be illuminated Filter Active If your Zip Hydroboil is specified with a filter the Filter Active text will normally be illuminated This indicated tha...

Page 9: ...Mounting Template Wall template for 10 15 25 40 litre models 374 10L 15L 25L 499 40L 295 15L 25L 420 40L 591 10L 15L 771 25L 831 40L 188 10L 15L 25L 313 40L EXTERNAL PLUMBING INTERNAL PLUMBING BENCH...

Page 10: ...Cistern Float S Nut Kit 10 90495 Banjo Screw Kit 11 90110 Fascia Light Kit 12 90501 Tap Top Kit 13 90499 Fascia Lens Kit 14 90494 Metering Tube Kit 2400 w 90527 Metering Tube Kit 3600 w 90526 Metering...

Page 11: ...Zip Hydroboil Installation Operating Instructions 81447 February 2004 Page 11 of 12 Spare Parts 1 20 19 18 21 17 16 14 13 15 12 11 9 8 7 6 5 4 3 2 4 4 8 8 4 10 17...

Page 12: ...st of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non opera...

Reviews: