Maintenance
• Cleaning the dispensing outlets, drip tray & outer surfaces must only be
undertaken with a clean sanitised cloth or disposable sanitise wipe.
• No chemicals should be sprayed onto the dispensing outlets at any time.
• Condenser - Brush clean the condenser of dust and lint at least every 3 - 6 months
(see page 13).
Temporarily putting out of service
• The water dispenser can be put out of service for a long period. However the specific
maintenance and safety precautions (see page 7) must be observed, upon re-
commissioning.
To empty the tank
(before moving)
• Isolate the mains water supply (see page 10).
• Remove the front cover.
• Hold a bucket under the tank drain connection (1)
• Remove the 5/16”end cap from the drain pipe (1)
located in the filter compartment.
• Press the chilled water dispense buttons.
• Drain the contents of the cold tank through the tank drain
connection (1) into the bucket. (The capacity of the
system is approximately 2.7 litres of water).
• Replace the end cap on the drain pipe & front cover.
1
General cleaning
• Dispense 10 litres of water to flush out any carbon residuals from the new filter.
• Close the isolation valve on the install rail.
• Remove the section of 1/4” filter flush pipe from the filter head outlet and
reconnect the original pipe.
• Re-open the isolation valve on the install rail (see page 10).
• Turn on the mains electrical power (see page 13).
• Dispense filtered water as required.
Notes
Lower performance of the dispenser in terms of cooling
should be considered normal when the inlet water
temperature is high, for example when the rear side is
exposed to the sun, or due to the increase in water temperature during summer.
• In case of freezing, unplug to disconnect the power supply and wait for defrost
before switching the power on again.