Spare Parts List

ITEM

KIT NO

DESCRIPTION

1

90126

CISTERN LID CLIP KIT EB

2

90127

OVERLOAD KIT EB

3

90128

CISTERN LID AND GASKET KIT

4

90115

GROMMET & GASKET KIT

5

90083

FLOAT VALVE KIT W/ FLOAT HS2000

6

90069

JUMPER VALVE KIT W/ SEALS

7

90108

O’RINGS & GASKET KIT

8

90102

CISTERN FLOAT KIT W/ NUT & SCREW

9

90495

BANJO SCREW HYDROBOIL 2000B

10

90501

TAP TOP KIT HYDROBOIL

11

90512

ESCUTCHEON KIT EB2000B

12

90502

TAP ASSY COMPLETE 

13

90081

THERMOSTAT KIT

14

90045

ELEMENT KIT 1500W  3Litre

14

90085

ELEMENT KIT 2400W  5-7.5Litre

15

90107

FILTER KIT COLD INLET BUSH

16

90175

DRAIN PLUG KIT MB/HB/AB/EB

STAINLESS STEEL CISTERN VERSION

17

90487

CISTERN LID CLAMP KIT HB/AB

18

90488

CISTERN LID & GASKET KIT

19

90779

CISTERN GROMMET & GASKET KIT EB SS CISTERN

20

90493

METERING TUBE KIT 1500W

20

90494

METERING TUBE KIT 2400W

Summary of Contents for Econoboil HS507

Page 1: ...2 v1 01 Page 1 of 12 Installation and Operating Instructions Zip Econoboil Budget priced instant boiling water for canteens and kitchens 103592 Zip Econoboil 3 0 litre White HS503 105592 Zip Econoboil 5 0 litre White HS505 107592 Zip Econoboil 7 5 litre White HS507 ...

Page 2: ...Page 2 of 12 Zip Econoboil Installation Operating Instructions 87546 May 2012 v1 01 This page intentionally left blank ...

Page 3: ...s 5 Step 1 Positioning 5 Step 2 Fastening 5 Step 3 Connecting 6 a Plumbing 6 b Venting 6 c Electrical 7 Step 4 Assembling 7 Step 5 Commissioning 7 Operating Procedures 7 Tap Operation 7 Cleaning Case 8 Earthing Continuity Verification 8 Problem Solving 8 Wall Mounting Template Dimensions 9 End of Life Disposal 9 Spare Parts List 10 Exploded View Diagram 11 Warranty Information 12 ...

Page 4: ... strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5ºC when the heater is not in use do not turn off the appliance electrically This safeguard does not offer the same protection to the connecting pipework and fittings The ambient temperatures this unit must operate within are 5ºC 50ºC This...

Page 5: ...will drain on to a draining board or drip tray Position the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for service access of not less than 150 mm top 65 mm left 20 mm right Mark corner positions for the heater on the wall so as to position the paper mounting hole template Step 2 Faste...

Page 6: ...sure limiting valve must be installed in the cold water supply line Zip recommends a valve rated at 3 5 bar for this application b Venting A vent at the base of the heater must be plumbed to a safe visible location as under certain conditions it may discharge cold or boiling water and or steam For exposed vent plumbing connect vent outlet from the base of heater to a 1 2 or 12 7 mm pipe which has ...

Page 7: ...tap one full rotation until the handle is fully vertical If the tap still feels loose continue to rotate one further turn leaving the tap in a vertical position Step 5 Commissioning Check previous steps Turn water supply ON Water is now flowing into heater check connections for leaks Wait approximately 5 minutes and check outlet tap for water This is acheived by pulling the tap handle forward Powe...

Page 8: ...al resistance does not exceed 1 ohm If required an earth continuity test can be performed by testing between the earth pin on the products lead and a exposed piece of metal on the case Operating Procedures continued Cleaning Case Do not use strong corrosive spray or abrasive cleaners Clean the case with a soft cloth or brush and mild soap and water Symptom Possible Cause Solution Fails to dispense...

Page 9: ... Page 9 of 12 Wall Mounting Template Dimensions Wiring Diagram 3 0 L 3 0 L 3 0 L 414 3 0L End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection centre details ...

Page 10: ...90102 CISTERN FLOAT KIT W NUT SCREW 9 90495 BANJO SCREW HYDROBOIL 2000B 10 90501 TAP TOP KIT HYDROBOIL 11 90512 ESCUTCHEON KIT EB2000B 12 90502 TAP ASSY COMPLETE 13 90081 THERMOSTAT KIT 14 90045 ELEMENT KIT 1500W 3Litre 14 90085 ELEMENT KIT 2400W 5 7 5Litre 15 90107 FILTER KIT COLD INLET BUSH 16 90175 DRAIN PLUG KIT MB HB AB EB STAINLESS STEEL CISTERN VERSION 17 90487 CISTERN LID CLAMP KIT HB AB 1...

Page 11: ...Zip Econoboil Installation Operating Instructions 87546 May 2012 v1 01 Page 11 of 12 Exploded View Diagram ...

Page 12: ...talled with the appliance as cartridge life may vary according to water quality and the rate of water consumption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted or modified as between the owner or user and Zip under the laws applicable Furthermore this warranty does not displace ...

Reviews: