Zip ChillTap Sparkling DOMCTS Installation And Operating Instructions Manual Download Page 10

Page 10 of 14 

Installation & Operating Instructions - 801957UK_DOMCTS - Zip ChillTap Sparkling - June 2014 V2.01

Operating Procedures 

continued

Filter Change

1.  Turn off the water and power supply to the unit.
2.  Turn the still water lever (blue ringed lever) on, to release any water    
 

pressure in the unit. Once water has stopped running from the tap turn off  

 

the lever.

3.  Turn the filter clock wise and gently pull the cartridge down. The cartridge  
 

should release from the filter head. Dispose of the filter cartridge  

 

 

responsibly. Clean any water that has pooled below the filter head.

4.  Fit a new filter by turning filter anti-clockwise and gently pushing up. The  
 

filter will click or lock into place.

5.  Turn the still water tap on.
6.  Turn on the water supply to the unit. Allow 7.5 litres to flow from the    
 outlet.
7.  Turn off the still water lever.
8.  Turn on the power supply to the unit. 

Warning

Not changing filtration cartridges when required, may cause the water to 
become biologically unsafe. 
Use only a Zip Filter to match that used with this ChillTap (if fitted). 
Replacement filter cartridges can be obtained through plumbing suppliers or 
directly from Zip.
Replacement instructions come with the filter cartridges.
Before attempting to disconnect or remove the filter cartridge from the housing, 
isolate (turn off) the water supply prior to the filter system, and then relieve the 
system pressure by operating the chilled water outlet tap until the water ceases 
to flow.

Gas Bottle Replacement:

1.  Turn off the water and power supply to the chilled sparkling unit.
2.  Turn off the regulator on top of the bottle. The regulator has a left hand   
 

thread, to turn off, turn anti-clockwise until shut.

3.  Remove the CO

2

 bottle from its mounting and unscrew from the regulator.

4.  Fit the new bottle, and turn on the regulator. Adjust the regulator to 0.27  
 

MPa (2.7 bar). Be aware that some CO

2

 may be discharged from the    

 

connection to the regulator as the bottle and the regulator are be  

 

 

assembled together. Any CO

2

 released will be cold. 

5.  Turn the sparkling lever to the on position. Leave it on until all the water  
 

has been purged through the tap. Let the tap run for a further 10 seconds  

 

to purge the CO

2

 

through the tank. Turn off the sparkling lever.

6.  Turn on the cold water supply first and then the power supply.
7.  Wait 20 seconds and then turn on the sparkling lever and wait for water to  
 

start to come through. 

8.  Dispense some sparkling water from the tap. Perform a taste test.

Service

There are no user serviceable parts but there are dangerous voltages present 
within the unit. All service work must only be carried out by a suitably qualified 
and experienced service person.
Before calling for service, check that both the water and electricity supplies are 
turned ‘ON’ and OK.
Call a licenced electrician, plumber, or Zip on 0845 6 005 005, for assistance, 
service, spare parts, or enquiries. 

Summary of Contents for ChillTap Sparkling DOMCTS

Page 1: ...ap Sparkling June 2014 V2 01 Page 1 of 14 Installation and Operating Instructions Zip ChillTap Sparkling DOMCTS Undersink filtered unfiltered chilled drinking water Filtered chilled still and chilled sparkling water Affix Model Number Label Here 801957UK DOMCTS GP ...

Page 2: ...t of the kit D Check the water quality to determine if extra filtration will be required A potable mains water supply must be used E Check the appliance rating plate and ensure correct power is available for the appliance F Check the underbench cupboard supporting the appliance is adequate for the total weight of the appliance Read all instructions and precautions before proceeding If in doubt or ...

Page 3: ... of the power supply cable must be appropriate for the power rating and location of the appliance The power supply cable must be adequately secured Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the power supply Take care when lifting the Zip ChillTap unit Some units may exceed safe lifting limits If you feel this is beyond your personal...

Page 4: ...ore disposal Do not expose to naked flame or any incandescent material Keep out of reach of children High concentration of gas may cause asphyxiation Use only in ventilated areas Use only in an upright position This bottle must be used with the approved pressure regulator Avoid shock Total Rating 0 14kW 230V AC Delivery Temperature Chilled 3 6 C Except under free flow conditions Sparkling 3 6 C Ex...

Page 5: ... where there is a minimum 52mm wide flat area within the draining area of the sink Make sure the selected position allows the carafe filler spout to overhang the sink bowl Use a 25mm sheet metal punch to create a neat hole without burrs Remove the large nut with the stainless steel and rubber washers from the base of the carafe filler leaving the rubber sealing ring o ring in place Fit the carafe ...

Page 6: ...cessible for servicing purposes Step C Installing the Filter Position the filter and filter head on the inside of a cupboard wall in a convenient position as close to the unit as possible but still allowing access to change the filter The filter head must be fastened to the cupboard wall in a position high enough to allow the removal and replacement of the filter cartridge Connect a length of John...

Page 7: ...rst depressing the collet and simultaneously pulling out the plug Measure and trim the 1 4 blue tube from the carafe tap to the JG fitting marked Still Outlet on the top rear of the chiller unit Before making connection insulate the tube with the loose length of the pipe insulation trim the insulation pipe to correct length which is about 10mm shorter than blue tube Push the blue tube fully into t...

Page 8: ...on Once satisfied that there are no leaks and with the regulator set at 0 27 MPa 2 7 bar refit the gas bottle to the Velcro strap and secure the bottle NOTE Care must be taken when working with high pressure carbon dioxide and in no cases should the normal operating pressure of 0 27 MPa 2 7 bar be exceeded WARNING A gas cylinder containing 1kg of CO2 should be installed in a well ventilated area o...

Page 9: ... should be no more than 35 C There must be a minimum 168cm of cupboard cross flow ventilation Suitable holes or vents will need to be cut into the cupboard and door For safe operation thoroughly flush the water through after non use periods longer than 24 hours Operation The lever on the right Blue rings is used for chilled still filtered water and the lever on the left White rings is used for chi...

Page 10: ...e filter system and then relieve the system pressure by operating the chilled water outlet tap until the water ceases to flow Gas Bottle Replacement 1 Turn off the water and power supply to the chilled sparkling unit 2 Turn off the regulator on top of the bottle The regulator has a left hand thread to turn off turn anti clockwise until shut 3 Remove the CO2 bottle from its mounting and unscrew fro...

Page 11: ...CO2 bottle Regulator to be set to 0 27 MPa 0 27 bar Internal fault Service Technician Contact local Zip Service Provider Poor levels of carbonation in drinks Incorrect CO2 pressure User Check CO2 regulator Supply pressure should be 0 27 MPa 2 7 bar adjust or replace as necessary Air in carbonation can User Purge system as described on page 9 Gas Bottle Replacement Residue in carbonation can Servic...

Page 12: ...e empty do not dispose of with general household waste but take to your local recycling centre Contact Zip Customer Service for advice on 0845 6 005 005 if further guidance is required End of Life Disposal Cleaning Do not use strong corrosive spray or abrasive cleaners chemicals Clean the casing tapware external filter piping and all other fittings with a soft cloth and mild soap and water Do not ...

Page 13: ...Installation Operating Instructions 801957UK_DOMCTS Zip ChillTap Sparkling June 2014 V 2 01 Page 13 of 14 Notes ...

Page 14: ...ceProviderorthecostofremoval cartageandre installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance the use of non authorised parts or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge instal...

Reviews: