Page 10 of 14
Installation & Operating Instructions - 801957UK_DOMCTS - Zip ChillTap Sparkling - June 2014 V2.01
Operating Procedures
continued
Filter Change
1. Turn off the water and power supply to the unit.
2. Turn the still water lever (blue ringed lever) on, to release any water
pressure in the unit. Once water has stopped running from the tap turn off
the lever.
3. Turn the filter clock wise and gently pull the cartridge down. The cartridge
should release from the filter head. Dispose of the filter cartridge
responsibly. Clean any water that has pooled below the filter head.
4. Fit a new filter by turning filter anti-clockwise and gently pushing up. The
filter will click or lock into place.
5. Turn the still water tap on.
6. Turn on the water supply to the unit. Allow 7.5 litres to flow from the
outlet.
7. Turn off the still water lever.
8. Turn on the power supply to the unit.
Warning
Not changing filtration cartridges when required, may cause the water to
become biologically unsafe.
Use only a Zip Filter to match that used with this ChillTap (if fitted).
Replacement filter cartridges can be obtained through plumbing suppliers or
directly from Zip.
Replacement instructions come with the filter cartridges.
Before attempting to disconnect or remove the filter cartridge from the housing,
isolate (turn off) the water supply prior to the filter system, and then relieve the
system pressure by operating the chilled water outlet tap until the water ceases
to flow.
Gas Bottle Replacement:
1. Turn off the water and power supply to the chilled sparkling unit.
2. Turn off the regulator on top of the bottle. The regulator has a left hand
thread, to turn off, turn anti-clockwise until shut.
3. Remove the CO
2
bottle from its mounting and unscrew from the regulator.
4. Fit the new bottle, and turn on the regulator. Adjust the regulator to 0.27
MPa (2.7 bar). Be aware that some CO
2
may be discharged from the
connection to the regulator as the bottle and the regulator are be
assembled together. Any CO
2
released will be cold.
5. Turn the sparkling lever to the on position. Leave it on until all the water
has been purged through the tap. Let the tap run for a further 10 seconds
to purge the CO
2
through the tank. Turn off the sparkling lever.
6. Turn on the cold water supply first and then the power supply.
7. Wait 20 seconds and then turn on the sparkling lever and wait for water to
start to come through.
8. Dispense some sparkling water from the tap. Perform a taste test.
Service
There are no user serviceable parts but there are dangerous voltages present
within the unit. All service work must only be carried out by a suitably qualified
and experienced service person.
Before calling for service, check that both the water and electricity supplies are
turned ‘ON’ and OK.
Call a licenced electrician, plumber, or Zip on 0845 6 005 005, for assistance,
service, spare parts, or enquiries.