Page 3 of 8
Zip ChillTap - Installation & Operating Instructions - CT1/140 - June 2013 v1.01
Technical Data / Installation requirements
• Power supply:
220-240V AC 50Hz for connection via a double pole switched fused spur with a minimum breaking
capacity of 13A. The circuit should be protected by a suitably rated RCD.
• Operating temperatures:
5ºC - 35ºC.
Installation Requirements:
• A potable water supply with a minimum supply pressure of 0.07 MPa - 0.7 MPa (0.7 bar to 7 bar).
For best results we recommend minimum static pressure of 0.2 MPa (2 bar).
• NOTE!
We recommend you supply and install an isolating valve in the supply line before the connection to the product as
an independent means of isolating the water in order to carry out maintenance or servicing.
• Site the chiller unit into the cupboard as close to the proposed outlet tap position as is possible to minimise the
length of tubing exposed between the chiller unit and the tap.
• Allow at least 50mm around the chiller unit to permit free airflow. Both the top and the front of the chiller must
remain accessible for servicing purposes.
Model
Chilled
Water
Chilled Water
glasses*
per hour
@ 5 - 10°C
Initial Draw
Glasses*
Recovery
Glasses*
Total
rating
Watts
Weight
Empty
Kg**
Weight
Full
Kg**
Under-Sink
W x H x D
CT1/140
ü
140
8
140
300
22.27
24.27
353 x 291 x 385
*Standard Glass = 200ml ** Weight is chiller unit only wit no accessories
Spare Parts & Accessories
Font Kit ........................................................... ZT004
Sub Micron Filter ............................................ ZT002
Pressure Reducer set at 0.35 MPa (3.5 bar) ... AQ3
*Water Block (Water Shut Down System) ........ HE45004
*The recommended optional Water Block is ideal for limiting potential leakage
and resulting water damage from water chillers and their supply pipe work
which are subject to mains water pressure.
It is easily installed via standard 3/4” BSP or 15mm push fit water connection
and can be pre-set from 5 to 50 litres. The Water Block also incorporates a
non-return valve.
HE45004
• This appliance must not be used by any person (including children) with limited physical, sensorial or mental
abilities or failing experience and / or knowledge unless they are supervised by a person responsible for their safety
or received instructions about how to use the appliance.
• Children should be supervised in order to make sure that they do not play with the appliance.
• The appliance must only be used when correctly installed and in perfect working order.
• This product is approved to the LVD and EMC directives and CE endorsed.
• Zip Heaters (UK) Ltd cannot be held liable for any damages caused by failure to observe these instructions.
Please leave these instructions with the end user after installation.
To ensure you have a copy of the latest instructions please visit www.zipheaters.co.uk.
Caution: Refrigerant
• The ChillTap contains R134a refrigerant under pressure. No part of the unit should be exposed to a naked flame.
• Maintenance of the refrigeration unit must be carried out by an accredited service provider or qualified refrigeration
mechanic.