Zip ChillTap - Installation & Operating Instructions - CT1/140 - June 2013 v1.01

Technical Data / Installation requirements

•  Power supply:

 220-240V AC 50Hz for connection via a double pole switched fused spur with a minimum breaking 

capacity of 13A. The circuit should be protected by a suitably rated RCD.

•  Operating temperatures:

 5ºC -  35ºC.

Installation Requirements:

•  A potable water supply with a minimum supply pressure of 0.07 MPa - 0.7 MPa  (0.7 bar to 7 bar).

  

For best results we recommend minimum static pressure of 0.2 MPa (2 bar). 

•  NOTE!

 We recommend you supply and install an isolating valve in the supply line before the connection to the product as 

an independent means of isolating the water in order to carry out maintenance or servicing.

•  Site the chiller unit into the cupboard as close to the proposed outlet tap position as is possible to minimise the 

length of tubing exposed between the chiller unit and the tap.

•  Allow at least 50mm around the chiller unit to permit free airflow. Both the top and the front of the chiller must 

remain accessible for servicing purposes.

Model

Chilled  

Water

Chilled Water  

glasses*  

per hour  

@ 5 - 10°C

Initial Draw  

Glasses*

Recovery  

Glasses*

Total  

rating  

Watts

Weight 

Empty

Kg**

Weight  

Full

Kg**

Under-Sink  

W x H x D

CT1/140

ü

140 

8

140

300

22.27

24.27

353 x 291 x 385

*Standard Glass = 200ml    ** Weight is chiller unit only wit no accessories

Spare Parts & Accessories

Font Kit ........................................................... ZT004 
Sub Micron Filter ............................................ ZT002
Pressure Reducer set at 0.35 MPa (3.5 bar)  ... AQ3
*Water Block (Water Shut Down System) ........ HE45004

*The recommended optional Water Block is ideal for limiting potential leakage 
and resulting water damage from water chillers and their supply pipe work 
which are subject to mains water pressure.
It is easily installed via standard 3/4” BSP or 15mm push fit water connection 
and can be pre-set from 5 to 50 litres. The Water Block also incorporates a 
non-return valve.

HE45004

•  This appliance must not be used by any person (including children) with limited physical, sensorial or mental  

abilities or failing experience and / or knowledge unless they are supervised by a person responsible for their safety 
or received instructions about how to use the appliance.

•  Children should be supervised in order to make sure that they do not play with the appliance.
•  The appliance must only be used when correctly installed and in perfect working order.
•  This product is approved to the LVD and EMC directives and CE endorsed.
•  Zip Heaters (UK) Ltd cannot be held liable for any damages caused by failure to observe these instructions.

Please leave these instructions with the end user after installation. 
To ensure you have a copy of the latest instructions please visit www.zipheaters.co.uk.

 Caution: Refrigerant

•  The ChillTap contains R134a refrigerant under pressure. No part of the unit should be exposed to a naked flame. 
•  Maintenance of the refrigeration unit must be carried out by an accredited service provider or qualified refrigeration  

mechanic.

Summary of Contents for ChillTap CT1/140

Page 1: ...illTap Installation Operating Instructions CT1 140 June 2013 v1 01 Page 1 of 8 Zip ChillTap Filtered chilled drinking water for the home Affix Model Number Label Here Installation and Operating Instru...

Page 2: ...t must be replaced by a Zip Service Engineer or a qualified electrician The power supply cable must be adequately secured and power outlet must be in a safe and accessible position after installation...

Page 3: ...ts Accessories Font Kit ZT004 Sub Micron Filter ZT002 Pressure Reducer set at 0 35 MPa 3 5 bar AQ3 Water Block Water Shut Down System HE45004 The recommended optional Water Block is ideal for limiting...

Page 4: ...l Slide the washer and nut over the tubes from under the sink and tighten the nut to secure the tap firmly into place Install the Filtration Unit The filtration unit should be mounted as close as poss...

Page 5: ...lastic tubing containing water under mains pressure be careful not to nick scratch or damage it during installation Ensure there is adequate ventilation available through the cupboard If there is inad...

Page 6: ...s long as you leave the lever in the open horizontal position When finished return the lever to the OFF upright position Maintenance Filter Replacement The Zip ChillTap Under Counter Chiller has a sep...

Page 7: ...Service for advice on 0845 6 005 005 Cleaning Service End of Life Disposal Never use strong corrosive or abrasive cleaning materials on the Zip ChillTap Wipe clean the outer surfaces with a sponge or...

Page 8: ...e use of non authorised parts or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge l...

Reviews: