Fix the bottom on the selected position with the inflated screw.   

 

Fix the sensor at the bottom and tighten the screw. Switch on the power and then you can 

test it. 

 

                                          OR 

 

Figure1                                        Figure2                                    Figure3                           

 

It not only can install on the wall directly but also can install in the inner corner or outer 

corner with the help of the widget (refer to photograph below): 

 

 

 

Flat mounted                      Inner corner mounted                  Outer corner mounted 

Note:  you  can  cut  the  plastic  cover  whatever 

shape  you  want  and  make  different  detection 

range. (refer to right figure)

 

 

 

CONNECTION-WIRE DIAGRAM:

 

(See the right figure) 
 

 

TEST:

 

 

Turn the TIME knob anti-clockwise on 

the  minimum  (10s).  Turn  the  LUX 

knob  clockwise  on  the  maximum 

(sun). 

 

Switch on the power; the sensor and 
its connected lamp will have no signal 

at  the  beginning.  After  Warm-up 

30sec, the sensor can start work .If the sensor receives the induction signal, the lamp will 

turn on. While there is no another induction signal any more, the load should stop working 

within 10sec

±

3sec and the lamp would turn off.

 

 

Turn LUX knob anti-clockwise on the minimum (3LUX). If the ambient light is more than 

3LUX, the sensor would not work and the lamp stop working too. If the ambient light is less 

than 3LUX  (darkness),  the sensor  would work.  Under no induction signal condition,  the 

sensor should stop working within 10sec

±

3sec. 

Note: when testing in daylight, please turn LUX knob to            (sun) position, otherwise 

the sensor could not work!   

 

Troubleshooting: 

 

The load does not work: 

a. Please check if the connection of power source and load is correct. 

b. Please check if the load is good. 

c. Please check if the settings of working light correspond to ambient light. 

 

The sensitivity is poor: 

a. Please check if there is any hindrance in front of the detector to affect it to receive 

the signals. 

b. Please check if the ambient temperature is too high. 

c. Please check if the induction signal source is in the detection field. 

d.  Please  check  if  the  installation  height  corresponds  to  the  height  required  in  the 

instruction. 

e. Please check if the moving orientation is correct. 

 

The sensor can not shut off the load automatically: 

a. Please check if there is continual signal in the detection field. 

b. Please check if the time delay is set to the maximum position 

c. Please check if the power corresponds to the instruction. 

 

 
 
 
 
 
Helpline 

If you receive this item with parts broken or missing, please telephone: 

0845-230-3400

 

Please have ready your name, address, tel. no., product reference, where purchased 

and parts required. An answering service is in operation outside office hours and during busy 

periods. 

We regret that we are unable to give advice on internal house wiring.

 