10.2.4 Installing IO-Link
NOTICE
Non-compliance may result in material damage.
If the wiring is done differently, the gripper will be damaged.
If the gripper has an additional STO cable (Safe-Torque-OFF), this is wired with the external safety circuit
independently of the SCM.
The pin assignments listed in the table are for both IO-Link channels.
IO-Link X1/IO-Link X2
1
3
5
2
4
6
IO-Link X1/IO-Link X2
M12 5-pin
socket
pin Color
Function
Explanation
pin Color
1
Black
C/Q
IO-Link communication
4
Black
2
-
-
-
6
-
3
White
+ 24 V DC
actuator
Actuator supply voltage
M12 5-pin socket
2
White
4
Gray
GND actuator
0 V DC actuator supply voltage
5
Gray
5
Brown
+ 24 V DC sensor
Supply voltage of sensor
1
Brown
6
Blue
GND sensor
0 V DC sensor supply voltage
3
Blue