www.zi
mm
er-instruments.com
1
|
16
2
.
Input and Output screens
In normal operation the user is presented with display test screen followed by version screen
to one of the output screen. These screens may be scrolled through one at a time
by pressing the “
Up key” or “
Down key”.
Screen 2 : Version Screen
ON O/P1 O/P2
COM
Zimmer
PRO
-V
INPUT x012
O/P 12 y012
A
A
ON O/P1 O/P2
COM
Zimmer
PRO
-V
Table 1: Measured parameters
Volt
Voltage
Measured parameters
Unit of Measurement
Screen 1 : Display Test
Output 1 as Voltage
Screen 3 : Voltage Input and
Output 1 as Current
Screen 4 : Voltage Input and
Output 2 as Current
Screen 6 : Voltage Input and
Output 2 as Voltage
Screen 5 : Voltage Input and
ON O/P1 O/P2
COM
Zimmer
PRO
-V
INPUT x012
O/P 12 y012
A
A
ZIMMER
PRO
-
V
Programmable Transducer
Installation & Operating Instructions
1. Introduction
The
Zi
mm
er
PRO
-
V
is a panel mounted 43.5X 65.5mm
Transducer.
The
Zi
mm
er
PRO
-
V
is used to measure and convert
AC
Voltage input into an
proportional DC current or voltage output signal.
Output signal generated
is proportional
to the
True RMS(upto 15th Harmonic) of the input Voltage.
Input Voltage and Output Voltage/Current is displayed on LCD and indicated by LED’s.
Section
Contents
1.
Introduction
2.
Input and Output screens
3.
Programming
3.1.1 Password Protection
3.1.1.2
New / Change Password
3.1.3 Communication Parameter selection
3.1.3.1 Address Setting
3.1.3.2 RS 485 Baud rate
3.1.3.3 RS 485 Parity selection
7.
Specification
5.
Installation
5.1
EMC Installation Requirements
5.2
Case Dimensions and Panel Cut-out
5.3
Wiring
5.4
Auxiliary Supply
5.5 Fusing
5.6 Earth / Ground Connections
6.
Connection Diagrams
RS 485 ( ModBus )
4.
15030988_Rev.A - 10/11
3.1.1.1 Password verification
3.1.2 Potential Transformer parameter selection
3.1.2.2 Potential Transformer secondary value
3.1.2.1 Potential Transformer primary value
3.1.4 Output Type selection
3.1.4.1 Output 1 Type selection
3.1.4.2 Output 2 Type selection
3.1.5 Input parameter selection
3.1.5.1 End value of input
3.1.5.2 Start value of input
3.1.5.3 Elbow Function Selection
3.1.5.4 Elbow value of input
3.1.6 Output parameter selection
3.1.6.1.1 End value of output 1
3.1.6.1.2 Start value of output 1
3.1.6.1.3 Elbow value of output 1
3.1.6.1 Output 1 parameter selection
3.1.6.2.1 End value of output 2
3.1.6.2.2 Start value of output 2
3.1.6.2.3 Elbow value of output 2
3.1.6.2 Output 2 parameter selection
Zi
mm
er
PRO
-
V
can be configured and
programmed at site for the following :
PT
Primary ,PT
Secondary,
Input parameters (i.e start, end and
elbow value of Input) and Output
parameters(i.e as Voltage or as Current
and start, end and elbow value of outputs).
The front panel has two push buttons through
which
the
user
may
scroll
through
the
output screens and configure the product.
1.1 LED Indication
Green LED
continuous ON
Aux. Supply healthy
condition
Output1 voltage
Output1 Current
Output2 voltage
Output2 Current
Green LED
continuous ON
Red LED
continuous ON
Green LED
continuous ON
Red LED
continuous ON
O/P 2
ON
O/P 1
LED
LED OPERATING
CONDITION
LED OPERATING
STATUS
3.1 Programming via Front LCD & Tow keys
3.2 Programming Via Programming port
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
INPUT x012
O/P 12 y012
A
A
INPUT
O/P 1
A
ON O/P1 O/P2
COM
Zimmer
PRO
-V
INPUT x012
O/P 12 y012
A
A
INPUT
O/P 1
ON O/P1 O/P2
COM
Zimmer
PRO
-V
INPUT x012
O/P 12 y012
A
A
INPUT
O/P 2
ON O/P1 O/P2
COM
Zimmer
PRO
-V
INPUT x012
O/P 12 y012
A
A
INPUT
O/P 2
A
ZIMMER
PRO
-
V
PRO
-
V