background image

Type:

 

MK/MKS/MKR/MKRS 

 

Version 1.8 /  07.05.2014

 

 

Clamping Elements 

 

 

ZIMMER GmbH,  Salmenkopf 5; D-77866 Rheinau-Freistett; TEL.: 0049/7844/9138-0; FAX: -80 

Assembly_Instructions_MK_MKR_v18.doc 

1/2 

Installation and Operating Instructions 

 

1.

 

Security Advice: 

 

Caution: 
Please read the complete documentation carefully before starting the set-up operation! 

1.1.

 

Depending on the type of application danger will be caused by: 

 

-

 

Contusion during installation caused by unsecured connecting construction 

-

 

Improper pneumatic connections 

-

 

Malfunction of pneumatic supply caused by pressure fluctuations or excessive heating 

-

 

Loose pneumatic connection 

-

 

Loose attachment screws 

-

 

removal of the spring cap 

-

 

Not turning off the operating instrument during installation or repair works at the clamping element 

-

 

Human malpractice 

-

 

Non-observance of the information and warning facilities during installation and the set-up operation 

 

Installation instructions have to be followed and the necessary equipment and supplies have to be used during installation, 
modifications,  maintenance  and  repair.  Throughout  every  working  process  on  the  clamping  elements  the  appropriate 
accident prevention regulations, VDE security and installation instructions have to be followed. 

1.2.

 

The  application  of  the  clamping  elements  –  in accordance  with  regulations – implies  that this  technology  will be utilized 
exclusively in consideration of the realm of possibilities defined by technical specification. All different ways of use exclude 
further liability of the Zimmer GmbH. 

 

2.

 

Model   MK/MKR (without spring storage), MKS/MKRS (inc. spring storage) 

 
The clamping element is preset to the appropriate track gauge ex factory. The contact sections are pressed onto the non-
attached  areas  of the  track  guide. Therefore, the process of clamping does not influence the precision and the economic 
lifetime of the track. 

2.1.

 

Operational Area: 

The MK/MKS models are designed for static use. The additional pressurizing on the side of the piston rod, termed as PLUS-
connection from now on, can increase the clamping power significantly (see 3.). 
 

-

 

max. surrounding temperature 70°C 

-

 

pneumatic operating pressure min. 5.5 bar, max. 8 bar 

-

 

check-up of all pneumatic connections in regular intervals  

 

Caution: 
Clamping processes during operation may cause damage of the clamping element as well as the linear guide. 

 

3.

 

MKS and MKS-Plus-Version 

 

The model MKS can be operated as a plain spring storage element or as a pressure supported spring repository element 
(PLUS-connection). The clamping power can be increased significantly by the pressure supported spring storage.  

 

Fig. 1 

Diagram of Connection 

 
 
 
 
 
 
 
 
 
 
 

 

3.1.

 

For a transportation lock, the spring energy storage is pre-stressed by a spacer between the contact sections. 

 

Caution: 
It is permitted to remove the transportation lock, only if the air connection is pneumatically pressurized to at least 5.5 
bar according to instructions.  
It is permitted to release pressure from the clamping element, only if an associated guide rail or a transportation lock 
exists! 

 

4.

 

PLUS-Version 

 

The application of the PLUS-Version strictly requires the removal of the air filter. The connection has to be replaced with a 
pneumatic connection.  

 

5.

 

Installation Instructions  

5.1.

 

General: 

For mounting the clamping elements, used screws have to comply with the category of solidity of min. 8.8. 
Attachment screws have to be tightened with the required moment. (Tab.1) 
The maximum holding load is reached only by a rigid connection construction which must cover the complete 
connection surface of the clamping element. 
 

Caution: The cap of the security clamping must not be removed, spring storage! 

5.2.

 

Installation / Uninstalling: 

-

 

Removal of the plastic blanking plug 

-

 

Attachment of M5 pneumatic connections, possibly attachment of PLUS-connection 

-

 

pressurize air connection to open the clamping element 

-

 

Set clamping element onto linear guide 

-

 

In case of using an adapter plate PMK, place this adapter plate between the clamping element and the  connecting 
construction as a device of leveling 

-

 

Turn the screws loosely into the screw threads 

-

 

Clamp model MKS by depressurizing 

-

 

Clamp model MK by pressurizing 

-

 

Tighten attachment screws with the required moment (Tab.1) 

-

 

For uninstalling perform in reverse order 

Standard -Connection 

Air Connection 

Air Filter 

PLUS -Connection 

PLUS-Connection 

Air Connection

Reviews: