10.3 Installing the energy supply
The integrated pin assignment supplies the
product and control system with power.
1
1
Signal transmission
10.3.1 Mounting the pin assignment
pin Function
Explanation
8|H
2|B
1|A
7|G
1|A
-
-
2|B
-
-
3|C
+ 24 V DC actuator
Actuator supply voltage
4|D
C/Q
IO-Link communication
5|E
FE
Functional ground
6|F
-
-
7|G
GND
8|H
+ 24 V DC sensor
Supply voltage of sensor