INSTALLATION AND OPERATING INSTRUCTIONS:
O-ring assembly gripper, pneumatic, GS series
11
Zimmer GmbH
•
Im Salmenkopf 5
•
77866 Rheinau, Germany
•
+49 7844 9138 0
•
+49 7844 9138 80
•
www.zimmer-group.com
EN / 2020-11-30
DDOC00228 / g
3
Expanding an O-ring
Ventilate connection A or A‘.
Ö
Spread jaws are extended.
Ö
O-ring is grasped and expanded.
3
A B
4
Positioning above the workpiece / plunging
Position the product above the workpiece in such a way that
the upper edge of the spread jaws and the lower edge of the
annular groove are aligned with one another.
Ventilate connection B or B‘.
4
A B
5
Wiper/installation
Ö
Wiper is extended.
Ö
As this happens, the spread jaws push the O-ring.
Ö
O-ring slides into the annular groove of the workpiece.
5
A
B
6
Return movement
Withdraw the product from the workpiece.
First, bleed connection B or B‘.
Ö
Wiper is retracted.
Then, bleed connection A or A‘.
Ö
Spread jaws are withdrawn.
Start of a new cycle.
6
A