DC Characteristics
41
DC Characteristics
Understanding proper DC current requirements for the eZ80
®
Develop-
ment Platform when application modules are plugged into it is very
important for developing applications. This section provides an estimate
of the average current requirement when different combinations of these
application modules are plugged in to the eZ80
®
Development Platform.
The receiver supply current is 90–150µA and the transmitter supply cur-
rent is 260mA when the LED is active. The measurements of current that
are shown in Table 24 are for the user’s reference. These values can vary
depending on the type of application that is developed to run with the
platform.
Table 24. DC Current Characteristics of the
eZ80
®
Development Platform with Different Module Loads
Platform/Modules Configurations
Current
Requirement (mA)
Status
eZ80
®
Development Platform
and eZ80F92 Flash Module
173
When connected only to a
power supply, and when
no program is running.
eZ80
®
Development Platform,
eZ80F92 Flash Module, and Modem
Module
174
When connected only to a
power supply, and when
no program is running.
eZ80
®
Development Platform,
eZ80F92 Flash Module, and
Thermostat Application Module
195
When connected only to a
power supply, and when
no program is running.
eZ80
®
Development Platform,
eZ80F92 Flash Module, Modem
Module, and Thermostat Application
Module
203
When connected only to a
power supply, and when
no program is running.
eZ80
®
Development Platform
and eZ80F92 Flash Module
325
When the LED demo is