User Manual
UM015201-0603
Jumper Settings
ZiLOG Development Platforms
eZ80
®
Sales Demonstration Platform
3
Jumper Locations
Figure 3 illustrates the jumpers on the eZ80
®
Sales Demonstration Platform.
Figure 3. eZ80
®
Sales Demonstration Platform Block Diagram
Jumper Settings
J1
CPU Acknowledgement for
Motorola Bus Mode
IN = enabled
OUT = disabled (default)
J3
External Flash Access on
eZ80
®
Module
IN = Flash access disabled
OUT = Flash access enabled (default)
J4
External Flash Boot Block Write
Access on eZ80
®
Module
IN = write enabled
OUT = write disabled (default)
J6
IrDA Control
IN = IrDA transceiver on the eZ80
®
module disabled (default)
OUT = IrDA transceiver on the eZ80
®
module enabled when
PB6 is set to 0
J12
COM2 (J11) Control
IN = Disabled
OUT = Enabled (default)
J14
COM1 (J13) Control
IN = Disabled
OUT = Enabled if PB6 set to 1 (default)