NOTES OR PREVENTIVE MEASURES                                                                                                                                                                                                       

1.  Environment 

1

  The machine can perform in environment where conditions are dry with a dampness level of max 90%. 

2

  Ambient temperature is between -10 to 40 degrees centigrade. 

3

  Avoid welding in sunshine or drippings. Do not let water enter the gas 

4

  Avoid welding in dust area or the environment with corrosive gas. 

5

  Avoid gas welding in the environment with strong airflow. 

2.  Safety norms 

Our  welding  machine  has  installed  protection  circuit  of  over  voltage,  over  current  and  over  heat.  When  voltage, 

output  current  and  temperature  of  machine  are  exceeding  the  rated  standard,  welding  machine  will  stop  working 

automatically. Because this will be damage to welding machine, user must pay attention to following.   

1

 

The working area is adequately ventilated

 

Our  welding  machine  is  powerful  machine,  when  it  is  being  operated,  it  generated  high  currents,  and  natural 

wind cannot satisfy with machine cool demands. So there is a fan inside the machine for its cooling demands. 

Make sure the intake is not in block or covered,  There should be 0.3 meter distance from welding machine to 

objects of environment. User should make sure the working area is adequately ventilated. It is important for the 

performance and the longevity of the machine.     

2

  Do not over load

 

The  operator should  remember  to  watch  the  max  duty  current  (Response  to the  selected  duty cycle)  Welding 

current should not exceed max duty cycle current. Over-load current will damage and burn up the machine. 

3

  No over voltage

 

Power  voltage can be  found  in  diagram  of main  technical data.  Automatic  compensation circuit of  voltage  will 

assure that welding current keeps is in allowable range. If power voltage is exceeding allowable range limits, it 

can  damage  the  components  of  machine.  The  operator  should  understand  this  situation  and  take  preventive 

measures. 

4

  There is a grounding screw behind welding machine,  with a grounding marker on it. Before operation, welding 

crust  must be grounded  reliably  with  cable  which  section is over  6  square  millimeter,  in  order  to  prevent  from 

static electricity, and accidents because of electricity leaking. 

5

 

If  welding  time  is  exceeding  duty  cycle  limited,  welding  machine  will  stop  working  for  protection.  Because 

machine  is  overheated,  temperature  control  switch  is  on  “ON’’  position  and  the  indicator  light  is  red.  In  this 

situation, you don’t have to pull the plug, let the fan cool the machine. When the indicator light is off, and the 

temperature goes down to the standard range, it can weld again.

 

 

 

 

 

 

 

 

Summary of Contents for Mini 160

Page 1: ...ZIKA OWNER S MANUAL Mini 160...

Page 2: ...s should be used to avoid breathing gases Arc rays Harmful to your eyes burn your skin Wear suitable protective mask light filter and protective garment to protect eyes and body Prepare suitable prote...

Page 3: ...it is easier to design into welding machine with different dynamic characteristics and it even can be adjusted for specialty to make arc softer or harder MMA welding machine has the following characte...

Page 4: ...ase AC220V 15 Frequency Hz 50 60 Rated input current A 23 9 MAX No load voltage V 65 Output current A 30 160 Rated output voltage V 26 4 Duty cycle 60 No load loss W 40 Efficiency 80 Power factor 0 73...

Page 5: ...at the polarity and fasten it clockwise 4 Put the fastening plug of the cable to fastening socket of polarity at the front panel fasten it clockwise and the earth clamp at the other terminal clamps th...

Page 6: ...they may adjust current of arc striking and be out of control of knob of welding current adjustment So machine can grain powerful energy and push current can achieve effect that may 5 If welding machi...

Page 7: ...f Mini 160 The panel picture above is for reference only If any difference with the real machine please follow with the real machine 1 Power switch 2 Abnormal indicator 3 Power indicator 4 Welding cur...

Page 8: ...e the working area is adequately ventilated It is important for the performance and the longevity of the machine 2 Do not over load The operator should remember to watch the max duty current Response...

Page 9: ...o big and stick s diameter is too small 2 Output terminal polarity connection is wrong it should apply the opposite polarity at the normal technique which means that the stick should be connected with...

Page 10: ...1K potential is bad replace it B Terminal of output is broken circuit or poor connect Fan is working and abnormal indicator is not lit there is no welding output A Check if components are poor connect...