Version Number: MIG200-20210914A1
15
2)
There is no response when turning on the power, please open the cover and check whether the internal
connecting wires are loose.
3)
The wire feeding is unstable. Please check the wire feeding reel and the wire feeding pressure roller,
and the welding gun should not be wound. Pay attention that the diameter of the welding wire matches
the wire feeding wheel groove and contact tip.
4)
No wire feeding, please confirm that the working mode is MIG state, please confirm that the welding
gun is connected well, press the gun switch or no wire feeding, please contact us.
5)
During the welding process, if the time exceeds 3 minutes, over-current protection may occur. You
need
to stop working for a few minutes, let the machine cool for a period of time, and automatically recover.
If
the air cools for more than 10 minutes, the machine does not automatically recover, please shut down
and restart.
6
)
If you have any questions, please contact us .
5.3 LIFT-TIG mode
MIG200 for thin plates with higher welding process requirements or welding with higher process
requirements, especially for stainless steel welding, you can use the LIFT TIG mode, which requires the use of
pure argon.
1.
Select “Lift TIG ” process.
2.
How to connect.