![zika I-PLAS60 User Manual Download Page 20](http://html1.mh-extra.com/html/zika/i-plas60/i-plas60_user-manual_3712654020.webp)
Figure 3-2: Back panel of I-PLAS60
No.
Part name
Function
1
Power switch
To control the ON/OFF of the input power of the machine.
2
Air reducer valve
To adjust the pressure of the input air.
3
Cooling fan
For heat dissipation through forced air cooling.
4
Cable
For power supply input.
5
Fuse holder
Tomount the fuse
3.2 Function of the components
Pilot arc terminal
The pilot arc terminal is the interface for the pilot arc wire lug of the cutting torch to connect the
machine. If it needs to connect the pilot arc wire lug of the cutting torch, rotate this terminal
counterclockwise to remove the cap, fix the wire lug, and then fix the cap back.
Interface for the cutting torch
This interface is with protective function, so electric shock caused by accidental touch of the
interface during working can be avoided.
2-pin aviation socket
The 2-pin aviation socket connects the control circuit. The control signal from the cutting torch
controls the start-up and stop of the machine through this aviation socket.
Quick socket
With this socket, the quick plug with work clamp can be installed and removed conveniently.
Fuse holder
When the input current is overly high and reaches a certain value, the fuse will break
automatically, the control circuit of the cutting machine will stop working, and the main circuit
will stop working consequently to protect the cutting machine from damage.
Filter