background image

   

   

   

   

zigencorp.com

 

 

Toll Free: 877-650-5252 

 

 

International: +1 818-654-5252 

Zigen HDMI 2.0 UHD 600 MHz 4x1 

Switch w/HDCP 2.2 & WebOS 

 

ZIG-SW41 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

USER MANUAL Ver. 1.0 

 
 

 
 

Summary of Contents for ZIG-SW41

Page 1: ...zigencorp com Toll Free 877 650 5252 International 1 818 654 5252 Zigen HDMI 2 0 UHD 600 MHz 4x1 Switch w HDCP 2 2 WebOS ZIG SW41 USER MANUAL Ver 1 0...

Page 2: ...e of Contents Copyright and Trademark 3 Introduction 4 Package Contents 4 Features 4 Specifications 5 Block Diagram 7 General Operation 8 Dip Switch Settings 8 Remote Control 10 WebOS 11 Command Synta...

Page 3: ...he registered trademarks referred to this manual are belonging to their respective companies Before You Begin Follow all instructions marked on the device during using Do not attempt to maintain the d...

Page 4: ...erence rooms for switching UHD content sources via multiple control options 3rd party controllers WebOS simple remote or front panel buttons High end home theaters for showing UHD 2 0 content with HDC...

Page 5: ...of bandwidth 2160P60 4 2 2 10 bit new Blu Ray would exceed the previous 10 2 GBPS maximum of HDMI 1 4a and would not be able to travel over category cable using HDBaseT as of this writing Chroma Subsa...

Page 6: ...DIF Digital Audio Output 1 x RJ45 LAN Port for TCP IP Control 1 x 9 pin RS 232 port 1 x 3 5mm IR In Port 1 x IR Sensor In 1 x 12 VDC Locking Connector Temperature Operating 32 122 F 0 50 C Humidity 20...

Page 7: ...zigencorp com Toll Free 877 650 5252 International 1 818 654 5252...

Page 8: ...e the SW41 in the default mode and it will pull the EDID from the connected selected display By being able to manage the EDID and HPD Hot Plug Detection you can speed up switching in mixed format syst...

Page 9: ...WebOS and custom EDID table can be loaded into the device This gives maximum flexibility as customers can load any EDID they want for the desired application Screen Shot EDID Tables in WebOS Note Whil...

Page 10: ...I pipeline and can be very useful to avoid a looping condition when multiple HDMI devices are connected in series ZIG SW41 Remote Control NEED TO INSERT SW41 remote control can be used for switching b...

Page 11: ...zigencorp com Toll Free 877 650 5252 International 1 818 654 5252...

Page 12: ...12 ZIG SW41 USER MANUAL SW41 Web OS Screenshot...

Page 13: ...IG SW41 XXXX last 4 digits of the serial number You should change it if you are using more than 1 device Change Name below to whatever you want ex CR100SW for conference room number 100 switcher Notes...

Page 14: ...re for internal use IP Address IP address of the unit assigned by your DHCP Server Hostname this is what you want to call the unit syntax example CR100RX_k123 This is also the name you type into your...

Page 15: ...er sp end of response Default RS232 Protocol Settings can be changed in WebOS if required Baud Rate 115200 Data Bits 8 Parity None Stop Bit 1 Flow control None IP DA14 XXXX sp parameter sp parameter s...

Page 16: ...mber Get Device Status SW41 XXXX st Shows active and inactive ports ex Port 1 active port 2 off etc HDMI Input Selection SW41 XXXX insel 1 2 3 4 Lets you change the input Audio Return Channel sw41 arc...

Page 17: ...d into ZIGEN products that are made by other manufacturers notably computer hard drives and liquid crystal display panels are limited to the term of the warranty offered by the respective manufacturer...

Reviews: