background image

USER MANUAL ZHS19

DOOR AND WINDOW SENSOR

ZHS19

MANUFACTURER INFORMATION

Dear Customer,

should you require technical advice and 

your retailer could not help please contact 

our technical support.

Schwaiger GmbH   

Würzburger Straße 17

90579 Langenzenn

Hotline: +49 (0) 9101 702-199

www.schwaiger.de

[email protected]

6.  Network removal of the device
Put the Gateway into removal mode by choosing 

„Home setup“ in the main menu and then click on 

„Add device“ (See images on the left). Then reset 

the device to default settings.

7.  Reset to default settings
Press the networking button for 5 seconds until 

the green LED starts to flash slowly.
Note: For network inclusion, the sensor must always be in the factory state.

LED indicator of devices

Network inclusion

Press the networking button for 2  

seconds until the green LED starts to flash 

(two times per second)

Network removal / Reset

The green LED flashes 6 times
(once per second)

Alarm (anti-tamper key)

The red LED flashes once

LED 

indicator

Sensor

Magnet

Anti-tamper key

Technical data

Working voltage

DC 3 V (2 x AAA battery)

Static current

≤ 5 µA

Alarm current

≤ 35 mA

Detecting distance

< 15 mm

Range

about 15 m (depending on building 

structure)

Working environment

-10°C ~ +50°C

Transmission power

<1 mW

Frequency range

2405-2480 MHz

Sensor dimension

76 x 36.6 x 16.5 mm

Magnet dimension

76 x 13.9 x 16.5 mm

Read these instructions before installing!

Do not use the device in any manner other than that specified in the manual. The 

manufacturer disclaims any guarantee if the device is used improperly.

 CAUTION!

The device is not a toy. Keep away from children and pets. The device cannot be repaired 

and must not be opened. 

Disposal

Do not dispose of batteries or electric and electronic devices in the normal house-

hold waste. The consumer is legally obliged to return electrical and electronic de-

vices and batteries that are at the end of their useful life to the point of sale or 

public collection points that have been set up for this purpose. Legislation in the 

country of use governs individual details regarding disposal. batteries should be disposed 

of separately. The symbol on the product, the user guide or the packaging indicates this 

legal requirement.

Declaration of conformity

Schwaiger GmbH hereby declares that the specified radio equipment product complies 

with Directive 2014/53/EU and other applicable directives. The complete EU declaration 

of conformity is available online at: http://konform.schwaiger.de

Explanation of symbols

 CAUTION! 

This symbol indicates a danger.

  NOTE: 

This symbol indicates important points.

3.  Networking button
Press the networking button (within the hole) for 2 sec-

onds until the green LED starts to flash fast, then let 

go. The device will be detected and included into the 

network.
4.  Installation of Door/Window Sensor
Select a place for installation. Remove the protective 

cover and stick the bracket to the place desired. The 

sensor should be installed at an immovable place, e.g. 

a door frame. The magnet can be installed on either 

side of the sensor at the movable part of the location 

(e.g. door panel, see example).

The distance between sensor and magnet should not 

exceed 15 mm.

5.  Attach the sensor to the bracket

Congratulations and thank you for purchasing the Schwaiger 

ZHS19 product. Below you will find useful operating guidelines. 

This is a smart door and window sensor which is based on the ZigBee Wireless Networking 

technology. It has a very low power consumption which makes for longer battery life. The 

sensor detects whether a door or window is opened or closed. Thanks to the dual sensor 

design, installation is even more flexible and adaptable.

Network inclusion

1.  Remove the protective  

  battery cover

 

2.  Put the Gateway into inclusion mode

Network inclusion of the sensor

Put the Gateway into inclusion mode. 
Remove the protective battery cover, press the networking button for 2 

seconds until the green LED starts to flash fast.

Please pay attention to the fact that during network inclusion, the distance 

between sensor and Gateway may not exceed 0.5 m.

ZHS19

Reviews: