ZAIoT-VTC01
13
6.2.
Vibration index report
Velocity rms (10Hz to 1kHz) in mm/s
Acceleration rms (10Hz~10kHz) in m/s2
Surface temperature of the measurement point in
℃
6.3. Power button and status indicator
Power button
Press and hold for 3 seconds to turn off the power
Press and hold for 3 seconds to turn on the power
Status indicator
Power on: blue light flashing (10ms every 1s for 5s)
Power off: red light flashing (10ms every 1s for 5s)
Complete acquisition and upload: green light flashing (10ms every 1s for 3s)
6.4. Battery replacement
When the platform reports a "low battery" alarm, please replace the battery
promptly. Replacement procedure
Unscrew the four screws securing the terminal housing and open the
housing by gently lifting upwards.
Unplug the old battery from the battery supply plug on the PCB.
Replace the battery with a new one, taking care to snap it in place and insert
the battery supply plug to the PCB.
Cover the housing gently and tighten the 4 fixing screws, taking care that the
side with the buttons and indicators corresponds to the front of the PCB.
The battery will automatically start the terminal registration when it is
powered up, the blue indicator light flashes, check at the platform if the