background image

FCC

 

WARNING

 

Any

 

Changes

 

expressly

 

or

 

modifications

 

not

 

approved

 

by

 

the

 

party

 

responsible

 

for

 

compliance

 

could

 

void

 

the

 

user's

 

authority

 

to

 

operate

 

the

 

equipment.

   

This

 

device

 

complies

 

with

 

part

 

15

 

of

 

the

 

FCC

 

Rules.

 

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

(1)

 

This

 

device

 

may

 

not

 

cause

 

harmful

 

interference,

 

and

 

(2)

 

this

 

device

 

must

 

accept

 

any

 

interference

 

received,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation.

 

Summary of Contents for Zeta IRZ1ZT92

Page 1: ...IRZ1ZT92 1 ZETA Motion Sensor...

Page 2: ...e Disclaimer This specification is preliminary and is subject to change at any time without prior notice ZiFiSense assumes no responsibility for any errors contained herein ZiFiSense is not responsibl...

Page 3: ...tion 4 2 Applications 4 3 Appearance 4 4 Features 4 5 Product parameters 5 6 Packing List 5 7 Installation 6 7 1 Screw 6 7 2 Adhesive 3M 8 7 3 Cable Ties 9 8 Use of Device 12 8 1 Power on 12 8 2 Suppo...

Page 4: ...s anti jamming devices and differential inputs so that the false detection is avoided 2 Applications Rooftops computer rooms important equipment rooms illegal entry detection operating position detect...

Page 5: ...ions Electrical Features Power supply Battery 2 ER14505 Battery capacity 2 2700 mAh Stand by current 10 A Working current 70 mA Physical Features Size 66 55 36 mm Enclosure material ABS Waterproof lev...

Page 6: ...g screw M3 20 2 device 2 4 expanded plastic pipe 2 3 Percussion drill 4 drill bit hammer 1 4 slotted screwdriver cross screwdriver 1 6 1 2 Installation instructions Open the device case Use a slotted...

Page 7: ...re the device in the mounting position Power on Insert the power plug into the upper power socket install two 14505 batteries remove the insulation sheet for the existing battery and close the upper c...

Page 8: ...2 2 Installation instructions Installation position Select a flat mounting position and clean it up Open the device case Use a slotted screwdriver to open the top cover from the bottom edge Power on I...

Page 9: ...m of the 3M adhesive and install the device to the specified position 6 3 Cable Ties 6 3 1 Auxiliary material No Materials Quantity 1 Metal cable ties 5 300mm 2 2 Slotted screwdriver utility knife 6 3...

Page 10: ...IRZ1ZT92 10 Fixation Pass the 2 cable ties through the device and secure to the installation rod opening Installation position...

Page 11: ...IRZ1ZT92 11 Power on Insert the power plug into the upper power socket install two 14505 batteries remove the insulation sheet for the existing battery and close the upper cover power socket...

Page 12: ...reshold for motion detected within the detection time range the sensor reaches the required number of triggers is determined as motion detected Default setting for motion detected is triggered 2 times...

Page 13: ...the user s authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference...

Page 14: ...IRZ1ZT92 13...

Reviews: