background image

 

TR800Web 

12280-0755-01

  

Seite

 

8 / 8 

www.ziehl.de 

  

 

Inputs 

 

 

Pt 100, Pt 1000  

-

199…+860 °C, according EN 60751 

 

KTY83, KTY84 

-

55…+175 °C, -40…+150 °C 

 

Thermocouples 

Type B, E, J, K, L, N, R, S, T    EN 60 584, DIN 43 710  

 

Voltage- / Current input 

0-10 V, 0/4-20 mA 

 

Measuring of resistance 

0,0 … 500,0 Ω , 0…30,00 kΩ 

 

Input Y1-Y2 

Reset, app. 18 VDC / 3,5 mA 

 

Input S1 and S2 

for contact or S0-interface 

Network-connection 

10/100 MBit  

Auto

-

MDIX

 

RS 485 interface 

 

 

Baud rate 

4800, 9600, 19200 Baud 

 

Parity 

N, O, E (none, odd, even) 

 

Wire length 

1000 m at 19200 Baud 

Test conditions 

EN 61010-1 

 

Rated impulse voltage 

4000 V 

 

Overvoltage category 

 

Contamination level 

III 

 

Rated insulation voltage Ui 

300 V 

 

On-time 

100 % 

 

Galvanic insulation / Test-voltage 

Ethernet 

– sensors 

 

 

 

DC 750 V 

 

Us  

– relays, sensors, Ethernet  

 

DC 3820 V 

 

Relays  

– sensors, Ethernet   

 

DC 3820 V 

 

Sensors 

– relays   

 

 

 

DC 3820 V 

 

No galvanic insulation 

RS485 

– sensors – reset input Y1/Y2 – S1 – S2 

Environmental conditions 

 

 

Ambient temperature range 

 

Storage temperature range 

 

Altitude 

 

Climatic conditions 

 

External wiring temperature range 

-20 °C ... +65 °C 
-

20 °C …+70 °C 

Up to  2000 m 

– 85 % rel. humidity, no condensation 

-

5 °C …+70 °C 

 

 

Housing 

Design V8, switchgear mounting 

 

Dimensions (W x H x D) 

140 x 90 x 58 mm 

 

Mounting height / w

idth

 

55 mm / 8 TE 

 

Wire connection, one wire 

each 1 x  1,5 mm

2

 

 

Stranded wire with insulated ferrules 

each 1 x  1,0 mm

2

 

 

Stripping length 

8 mm 

 

Torque of screw 

0,5 Nm (3,6 lb.in) 

 

Protection class housing / terminal 

IP 30 / IP 20 

 

Fitting position 

any 

 

Installation 

Snap mounting on mounting rail 35 mm according to  EN 
60 715 or with screws M 4  

(2 additional bars, not included

 

in delivery)  

Weight 

app. 370 g 

 
 

Subject to technical changes 

 
 
 

Summary of Contents for TR 800 Web

Page 1: ...hift delay is running Flashes uniformly 1 1 Ready for reset reset with key Press SET RESET 2s or ext Reset Y1 Y2 5 LED yellow Night Illuminated Limits for Night can be set via browser are active 6 LED...

Page 2: ...maximum temperature permissible when installing in switching cabinet Make sure sufficient space to other equipment or heat sources If the cooling becomes more difficult e g through close proximity of...

Page 3: ...T3 to 8T3 and RESET Y1 Y2 S1 S2 are not potentially separated from output RS485 Temperature sensors must have a sufficient insulation Only signals according to SELV Safety Extra Low Voltage may be con...

Page 4: ...84 8th 8 thermocouples 80 108 voltage input 0 10 V 80 208 current input 0 20 mA 84 208 current input 4 20 mA 8r5008 resistance 500 Ohm 8r30 08 resistance 30 K Ohm 8diff8 difference 8IP 8 IP address 8I...

Page 5: ...rowser and enter the IP address in the address line Return The TR800Web homepage opens in the web browser Close the login window with the OK button without user name and without password If the networ...

Page 6: ...k browser network environment Symbols for show Network UPnP devices must be active Double click on the device found The TR800Web homepage opens in the web browser Close the login window with the OK bu...

Page 7: ...ay Er 8 appears in the digital display Cause Internal device error Remedy Switch unit off and back on If the error message continues to appear the unit must be returned to the factory for repair User...

Page 8: ...rs DC 750 V Us relays sensors Ethernet DC 3820 V Relays sensors Ethernet DC 3820 V Sensors relays DC 3820 V No galvanic insulation RS485 sensors reset input Y1 Y2 S1 S2 Environmental conditions Ambien...

Reviews: