STWA1FH
12060-0701-03
Page
3 / 4
www.ziehl.de
5
Technical Data
Supply-voltage Us
DC 10 ... 30 V
typ. <15 mA, max. 22 mA
Ripple
max. 5 %
Output OUT
Transistor
Switching voltage
max. DC 30 V
Switching current
max. DC 30 mA
Frequency of monitored current
Functional range
50 ... 400 Hz
Nominal frequency
50 Hz
Error
≤ 0.2 % / Hz
Frequency Output
maximum frequency
at overcurrent
Monitoring range
0 ... 20 A
0,5 ... 20 Hz
< 40 Hz
Options:
0 ... 40 A
0,5 ... 40 Hz
< 80 Hz
0 ... 60 A
0,5 ... 60 Hz
< 120 Hz
0 ... 80 A
0,5 ... 60 Hz
< 120 Hz
0 ... 50 A
10 ... 1000 Hz
< 2000 Hz
Adjustment time
< 0.5 s
Error (from 10 % / I
nom
)
2 % from Range
Temperature coefficient
< 0.06 % / K
Overload Capacity
continuously
I
N
+5%
max. 10 s
200 A
Test Conditions
EN 61010
Rated impulse withstand voltage
4000 V
Overvoltage category
III
Pollution degree
2
Rated insulation voltage Ui
250 V
On-period
100 %
Rated ambient temperature range
0 ... 55 °C
EMC-immunity
EN 61326 (industrial electromagnetic environment)
EMC-emission
EN 61326 CISPR 11 class B
Vibration resistance EN 60068-2-6
2...25 Hz ±1.6 mm
25...150 Hz 5 g
Housing
design H
Line connection
each 1 x 0.08 mm
2
to 1.5 mm
2
Protection terminals
IP 20
Mounting position
any
Weight
ca. 90 g