date / name ) : 06.09.07 WL / Fz/Fu
Z. Nr.: 12110-0710-01
Page 11 of 12
Type: Minipan 300
ZIEHL industrie-elektronik GmbH + Co KG, Daimlerstr.13, D-74523 Schwäbisch Hall, Tel.: +49 791 504-0, Fax: -56, e-mail: [email protected]
Technical data
Power Supply
Rated supply voltage Us
AC/DC 24-240 V
Tolerance DC
DC 20 - 297 V (0,85 x 24 V...1,35 x 220 V)
Tolerance AC
AC 20 - 264 V (0,85 x 24 V...1,1 x 240 V)
Power consumption
< 3 VA
Frequency
48...62 Hz
Measuring Inputs
insulated from supply-voltage
(connect 1 input only)
DC-Meter
±
300 mV
/ 120 k
Ω
/ max. ±2,5 V
Measuring range / resistance of input ±
10.00 V
/ 1 M
Ω
/ max. ±50 V
/ overload capacity
± 500.0 V
/ 3 M
Ω
/ max. ±600 V
± 100.0 V
/ 3 M
Ω
/ max. ±600 V
± 20.00 mA
/ Shunt 15
Ω
/ max. ±100
±
1.00 A
/ Shunt 150 m
Ω
/ max. ±2 A
AC-Meter
150 mV
/ 900
Ω
/ max. 2,5 V
Measuring range / resistance of input
10.00 V
/ 100 k
Ω
/ max. 50 V
/ overload capacity
50.0 V
/ 1 M
Ω
/ max. 60 V
500.0 V
/ 3 M
Ω
/ max. 600 V
1.00 A
/ Shunt 150 m
Ω
/ max. 2 A
Measuring time AC/DC
< 400 ms + delay of display
ddis
Pt 100- Meter
- 199,9 ... + 850,0
°
C
(= -328 ... +1563 °F)
Sensor-connection
Pt 100, 2- or 3-wire
Wire-resistance 3-wire
max. 3 x 50
Ω
Measuring time temperature
< 400 ms + delay of display
ddis
Accuracy
Resolution
+9999 / -1999
Error (of full measuring range)
DC voltage and current
± 0,1 % ± 1 Digit
AC voltage and current
± 0,5 % ± 1 Digit
Temperature factor
± 0,02 % / Kelvin
Total error
At Pt 100- Meter
± 0,3 % of value ± 0,5 K
Temperature factor
± 0,03 °C / K
Test conditions
EN 50178 / EN 61010-1
EN 61326-1 industrial applications
Measuring category
CAT II 600 V DOUBLE INSULATION
CAT III 300 V DOUBLE INSULATION
Contamination level
2
On-time
100 %
Rated ambient temperature range
-20 °C ... +60 °C
EN 60068-2-1 dry heat
Vibration resistance EN 60068-2-6
2…25 Hz ±1,6 mm
25 ... 150 Hz 5 g