4
Saving the parameter values of the ZETADYN 3C
In order to continue operating the elevator with the same travel properties, the same parameter
settings must be made on the ZAdyn4C as on the ZETADYN 3C. The parameter values of the
ZETADYN 3C must therefore be saved.
There are two ways of ensuring the parameter values:
•
Noting the parameters of the ZETADYN 3C
•
Saving the parameters of the ZETADYN 3C
4.1
Noting the parameters of the ZETADYN 3C
"
Note the parameter values of the ZETADYN 3C in the chapter "Con
fi
guring the ZAdyn4C/Manual
setting of the parameter values" in this technical information sheet in the parameter list behind the
parameter names. After mechanical and electrical installation, you can set the parameter values on
the ZAdyn4C.
4.2
Saving the parameters of the ZETADYN 3C
Alternatively, you can save the parameters of the ZETADYN 3C on an SD card and load the
parameters into the ZAdyn4C via the SD card after mechanical and electrical installation.
"
Insert the memory card in the X-MMC card slot on the controller unit (see
fi
gure).
Memory card in the X-MMC card slot
Statistics
->Memory Card
MMC Recorder
Encoder-adjust.
Select
"Memory Card"
menu
Con
fi
rming menu selection
Memory Card
|
-
"
SAV_PAR OFF
|
-
"
ON
Select
"SAV_PAR"
parameter
Con
fi
rming menu selection
Select "SAV_PAR=EIN"
Con
fi
rm with the key.
Please wait ...
Copy1:_ _ _ _ _ _ _
The parameters are saved.
After saving the parameters on a PC or laptop, the SD card must be manipulated so that the data can
be read in by the ZAdyn4C:
"
Rename the
fi
le path from "3BF" to "4CX".
Changing the
fi
le path
Technical Information
Saving the parameter values of the ZETADYN 3C
R-TIA19_02-D-GB 1942
Part.-No. 00163469-D-GB
5/26