6
Electrical installation
6.1
General
Attention!
Parts can be destroyed by electrostatic discharge.
Discharge yourself by suitable action before working on electrical components (connectors, etc.). You can do this,
for example, by touching earthed metal parts.
Refer to the ZAdynpro wiring diagram in this technical information and the ZAdynpro operating
instructions.
6.2
Terminal positions
6.2.1
ZETADYN 3C011 to 3C074
X1
X-EXT
X-BC
X-CO
X-I
X-O
X-BR
X-ENCO
X-CAN / X-AN
X-DCP
X-PAD
X-MMC
X-MT
X-ENC8 / X-ENC9 / X-ENC15
Terminal positions
X1
Mains / Motor / Brake-Chopper / Brake-Resistor
X-EXT
external 24 V external power supply
X-BC
Temperature monitoring of Brake-Chopper / Brake-Resistor
X-CO
Contactor monitoring
X-I
Digital inputs
X-O
Digital outputs
X-MMC
Memory card
X-PAD
ZETAPAD
X-DCP
DCP
X-CAN
CAN
X-ENCO
Encoder simulation
X-BR
Motor brake monitoring
X-ENC8
Encoder
X-ENC9
Encoder SUB-D
X-ENC15
Absolute encoder SUB-D
Technical Information
Electrical installation
R-TIA19_04-D-GB 2030
Part.-No. 00163470-D-GB
3/26