background image

6.9

Digital outputs (X-OUT)

CAUTION!

Attention!

Observe minimum and maximum switching capacity.

 

X-OUT1

X-OUT2

Min. switching ca-
pacity

5 mA / 12 VDC

5 mA / 12 VDC

Max. switching ca-
pacity

2 A/250 VAC

500 mA/24 VDC

ZETADYN 3BF

 

ZAdynpro

Digital outputs (X-OUT)

 

Digital outputs (X-OUT1, X-OUT2)

O11/O14

(1), (2)

->

O11/O14 

X-OUT1 (1), (2)

O21/O24

(4), (5)

->

O21/O24 

X-OUT1 (3), (4)

O31/O34 

(7), (8)

->

O31/O34 

X-OUT1 (5), (6)

O41/O44 

(10), (11)

->

O41/O44 

X-OUT2 (1), (2)

 

 

 

O51/O54 

X-OUT2 (3), (4)

Connection terminal X-OUT ZETADYN 
3C

 

Connection terminal X-OUT1 
ZAdynpro 011-032

Connection terminal X-OUT2 
ZAdynpro 011-032

 

 

Connection terminal X-OUT1 
ZAdynpro 040-074

Connection terminal X-OUT2 
ZAdynpro 011-032

Technical Information 

Electrical installation

R-TIA19_04-D-GB 2030

Part.-No. 00163470-D-GB

11/26

Summary of Contents for ZETADYN 3BF

Page 1: ...ve this provision can lead to serious injury Work on electric components may only be carried out by trained electricians or by persons instructed in electricity under the supervision of an electrician...

Page 2: ...tallation the parameters can be loaded to the ZAdynpro using the memory card see Parameterisation of the ZAdynpro chapter Procedure for saving the parameters on the memory card Insert the memory card...

Page 3: ...to 3C074 X1 X EXT X BC X CO X I X O X BR X ENCO X CAN X AN X DCP X PAD X MMC X MT X ENC8 X ENC9 X ENC15 Terminal positions X1 Mains Motor Brake Chopper Brake Resistor X EXT external 24 V external powe...

Page 4: ...tor brakes 6 J4 terminating resistance CAN line 7 X CAN CAN DCP 8 X ENC15 rotary encoder SUB D 9 X ENCO rotary encoder simulation 1 2 3 4 Position of connection terminals on bottom 1 X3 motor 2 X STO...

Page 5: ...ne 7 X BR inputs for function monitoring of the motor brakes 8 X BC temperature monitoring for brake resistor brake chopper 9 X IN digital inputs 10 X OUT2 digital outputs 11 X MMC memory card 1 2 3 4...

Page 6: ...ors 7 Brake resistor cable shielded 8 Motor cable shielded 9 Shielding brake resistor cable 10 Clip for contacting the shielding ZAdynpro 1 ZAdynpro mains connection terminal 2 Power line 3 Motor cabl...

Page 7: ...al 2 Power line 3 Motor cable shielded 4 Clip for contacting the shielding 5 Route electrical lines with the maximum possible spacing 6 Line reactor 7 Mains supply terminal 8 Brake resistor cable shie...

Page 8: ...or temperature monitoring can be performed using the tripping device type U EK230E part no 382008 The motor temperature monitoring is connected to the connection terminals T1 T2 on the tripping unit T...

Page 9: ...tor ZETADYN 3BF X BC ZAdynpro X BC ZETADYN 3BF ZAdynpro Temperature monitoring brake chop per brake resistor X BC Temperature monitoring brake chop per brake resistor X BC 24 V 2 24 V 1 BC 3 BC 2 PE 4...

Page 10: ...yn4C Digital inputs X I Digital inputs X IN 24V 1 24V 1 24V_IN 2 24V_IN 2 I01 3 I01 3 I02 4 I02 4 I03 5 I03 5 I04 6 I04 6 I05 7 I05 7 I06 8 I06 8 I07 9 I07 9 I08 10 I08 10 GND_IN 11 GND_IN 11 GND 12 G...

Page 11: ...OUT1 X OUT2 O11 O14 1 2 O11 O14 X OUT1 1 2 O21 O24 4 5 O21 O24 X OUT1 3 4 O31 O34 7 8 O31 O34 X OUT1 5 6 O41 O44 10 11 O41 O44 X OUT2 1 2 O51 O54 X OUT2 3 4 Connection terminal X OUT ZETADYN 3C Connec...

Page 12: ...nnection adaptor connector D SUB 15 article number 00152676 is to be used The single cores must be connected to the adaptor connector as set out in the table ZETADYN 3BF ZAdynpro Encoder connection as...

Page 13: ...L GL 004 HX ZA ASM 9 15 Article no of the adapter 00165930 004M ZETADYN 3BF ZAdynpro Encoder connection asynchronous mo tors X ENC9 Encoder connection asynchronous mo tors X ENC15 SUB D 9 pole SUB D 1...

Page 14: ...DYN 3BF and the ZAdynpro The connecting cable can be reconnected directly from the ZETADYN 3BF to the ZAdynpro ZETADYN 3BF ZAdynpro Encoder connection synchronous mo tors X ENC15 Encoder connection sy...

Page 15: ...P DCP interface X CAN DA 1 DCP_A 4 DB 2 DCP_B 2 0VD 3 GND_COM 1 4 3 Connection terminal X DCP ZETADYN 3C Connection terminal X ENC15 ZAdynpro 011 032 Connection terminal X CAN DCP ZAdynpro 040 074 Tec...

Page 16: ...ce X CAN CH 4 CH 4 3 3 CL 2 CL 2 0VC 1 0VC 1 Connection terminal X CAN ZETADYN 3BF Connection terminal X CAN ZAdynpro 011 032 Connection terminal X CAN ZAdynpro 040 074 To activate the terminating res...

Page 17: ...3 Y 4 Y 2 Y 3 Y 1 GND 2 1 1 1 The screening of the cable must be connected on the control side Connection terminal X ENCO ZETADYN 3BF Connection terminal X ENCO ZAdynpro 011 032 Connection terminal X...

Page 18: ...onitor X BR 24V_B 6 24V_OUT 5 BR1 5 BR1 4 BR2 4 BR2 3 BR3 3 BR3 2 BR4 2 1 Connection terminal X BR ZETADYN 3BF Connection terminal X BR ZAdynpro 011 032 Connection terminal X BR ZAdynpro 040 074 Techn...

Page 19: ...ty related via a digital input with the function STO Info or STO Info If the state is requested via a digital output the digital output has to be con gured in the control system menu to STO Info or ST...

Page 20: ..._PAR parameter Con rming menu selection Enter LOD_PAR 327 Con rm with the key Please wait Copy1 _ _ _ _ _ _ _ The parameters are loaded Technical Information Con guration of the ZAdynpro R TIA19_04 D...

Page 21: ...1 N PE Drehgeber Encoder Asynchronmotor Asynchronous motor Bremsl ft berwachung Brake release monitoring Aufzugsteuerung Elevator controller Option Option F1 F3 F2 Bremswiderstand Brake resistor R BC...

Page 22: ...tgeber Absolute encoder Synchronmotor Synchronous motor Bremsl ft berwachung Brake release monitoring Aufzugsteuerung Elevator controller Option Option F1 F3 F2 Bremswiderstand Brake resistor R BC 24...

Page 23: ...9 3 Circuit suggestion for ZAdynpro Technical Information Circuit suggestions R TIA19_04 D GB 2030 Part No 00163470 D GB 23 26...

Page 24: ...S_B_OFF Encoder BC menu Monitoring menu ENC_TYP MOD_ST ENC_INC STO BC_TYP LOCKBR R_BR Ohm CO P_BR kW BR T_PFU s P1P2 R_P1P2 Installation menu T_ENC V m s T_SDLY MOD_n T_CO n rpm T_CDLY _D m T_BR _iS S...

Page 25: ...eter set 2 V_Z F_PAR2 V_4 U_ACCU V_5 P_UPS V_6 RS_UPS V_7 STOP Copy Deceleration menu A_NEG Menu encoder calibration for synchronous motors R_NEG1 ENC_OFF R_NEG2 S_DI3 Menu CAN for CAN control S_DI2 L...

Page 26: ...hanges Customer Service phone 49 7940 16 308 fax 49 7940 16 249 drives service ziehl abegg com Headquarters Ziehl Abegg AG Heinz Ziehl Stra e 74653 K nzelsau Germany phone Tel 49 0 7940 16 0 fax Fax 4...

Reviews: