background image

4.3.8

Measuring report

System:

 

Elevator:

 

Gear type:

 

Gear serial number:

 

Year of construction:

 

Gear ratio:

 

Number of trips:

 

Measuring instrument:

 

Measurement performed by:

 

Measurement performed on:

 

Measured values:

Outer diameter of traction sheave

D

a

 

mm

Distance from outer diameter to measuring point

a

 

mm

Measuring radius

R

a

meas

a

2

=

D

+

 

mm

Measured clearance, measurement 1

c

meas_1

 

mm

Measured clearance, measurement 2

c

meas_2

 

mm

Measured clearance, measurement 3

c

meas_3

 

mm

Measured clearance, measurement 4

c

meas_4

 

mm

Measured clearance, measurement 5

c

meas_5

 

mm

Measured clearance, measurement 6

c

meas_6

 

mm

Largest measured clearance from all 6 measure-
ments

c

meas

 

mm

Calculation of current 

ank clearance:

Reference radius

r

260

mm

Current 

ank clearance

< 3 mm.
< 2.2 mm.*

c

curr

c

meas

=

r

R

meas

*

 

mm

* if very distinctive pitting

Service instructions 

ZAS0, ZAS1, ZAS2, ZAS3

Flank backlash measurement

A-TIA19_07-GB 1936 Index 001

Part.-No. 01013457-GB

10/12

Summary of Contents for ZAS Series

Page 1: ...ZIEHL ABEGG SE Heinz Ziehl Stra e 74653 K nzelsau Tel 49 7940 16 0 drives ziehl abegg de www ziehl abegg de A TIA19_07 GB Article no 01013457 GB Issue 1936 Index 001 Erstellt am 02 09 2019 ZAS0 ZAS1 Z...

Page 2: ...4 Flank backlash measurement 6 4 1 General information 6 4 2 Simpli ed ank clearance measurement 6 4 2 1 Requirements 6 4 2 2 Procedure 6 4 3 Comprehensive ank backlash measurement 8 4 3 1 Tools requi...

Page 3: ...le No 01008067 GB A TBA13_04 GB A current hardcopy version of the original operating instruction and this service manual must be available at the drive 2 Safety instructions 2 1 Pictographs Safety ins...

Page 4: ...going training instruction or on apprenticeship may only work on the elevator machine under the supervision of an experienced person This also applies to personnel in general training Comply with the...

Page 5: ...cking varnish must be undam aged every year Check the distance between the set ting screw for the micro switch and adjust if necessary Check the vicinity of the clutch for unusual wear articles every...

Page 6: ...Attention If the ank clearance exceeds the maximum permitted value the elevator machine may no longer be used on safety grounds An inadequate tooth width can lead to breakage 4 2 Simpli ed ank clearan...

Page 7: ...7 2 27 2 9 ZAS2 SWG2 260 46 1 46 1 35 ZAS2 SWG2 260 38 1 38 1 29 ZAS2 SWG2 260 28 1 28 1 21 ZAS2 SWG2 260 45 2 45 2 17 ZAS2 SWG2 260 35 2 35 2 13 ZAS2 SWG2 260 27 2 27 2 10 ZAS3 SWG3 280 46 1 46 1 37...

Page 8: ...nd 20 N to 50 N of force until a stop is detected This stop point is the reference for the measurement The traction sheave is then moved in the other direction until it reaches a stop again The measur...

Page 9: ...D Measurement radius in mm cmeas Measured clearance in mm relative to measurement radius 4 3 5 Table values cmax Maximum permitted ank clearance r Reference radius in mm for the maximum permitted ank...

Page 10: ...cmeas_1 mm Measured clearance measurement 2 cmeas_2 mm Measured clearance measurement 3 cmeas_3 mm Measured clearance measurement 4 cmeas_4 mm Measured clearance measurement 5 cmeas_5 mm Measured clea...

Page 11: ...er supply using the main switch secure it against being switched back on and check that there is no voltage Do not activate the manual hand release Inspection goal Identi cation of loose nuts Inspecti...

Page 12: ...cal changes Customer Service phone 49 7940 16 308 fax 49 7940 16 249 drives service ziehl abegg com Headquarters ZIEHL ABEGG SE Heinz Ziehl Stra e 74653 K nzelsau Germany phone 49 7940 16 0 fax 49 794...

Reviews: