Lift the elevator machine:
"
Only at the designated attachment points (see Figure 3-3-2-01).
"
At all attachment points at the same time.
"
Using suitable lifting gear.
"
Correctly taking into account the centre of gravity.
"
Without additional loads.
"
Do not lift at the end face in the shaft ends.
3.4
Storage
"
Store the elevator machine in the original packaging in a dry area protected from the weather or
protect it from dirt and weather until
fi
nal mounting.
"
Extreme heat or cold (storage temperature -20
°
C to +60
°
C) must be avoided!
"
High humidity which can lead to condensation must be avoided.
"
Avoid aggressive conditions (for example salt spray)!
"
Avoid excessive storage times (we recommend max. one year) and check bearing for correct
function before installing the motor. (Release the brakes and move the rotor by hand. Take care if
the bearing makes untypical noises)
3.5
Disposal / recycling
Disposal must be carried out professionally and environmentally friendly in accordance with the legal
stipulations.
4 Mechanical installation
4.1
General mounting advises
Mounting, electrical connection and commissioning are only to be performed by trained service
personnel. Adhere to all machinery-related requirements and speci
fi
cations supplied by the system
manufacturer or machine builder.
CAUTION!
Attention!
"
Cover the elevator machine and particularly the brakes appropriately when carrying out any work in
or on the elevator that results in dust or chips!
"
Do not install distorted.
"
Do not apply any force (levering, bending). Above all, do not expose the rotor to any heavy
mechanical shocks.
"
Before assembly, the elevator machine must be checked for transport damage, particularly the
cables.
"
No welding work may be carried out on the elevator machine. The elevator machine may not be
used as a grounding point for welding work. Magnets and bearings can be destroyed!
"
The cooling air
fl
ow around the elevator machine must not be obstructed.
"
We rcommend keep at least 300 mm space between the brake and the wall (axial direction) to make
access to the encoder possible.
"
The brake design with manual hand release must be freely accessible since the levers for
brake release are moved laterally (see chapter
“
Start-up / manual emergency evacuation)
”
!
Original operating instructions
ZAtop
–
model series SM250.60B
Mechanical installation
A-TBA20_02-GB 2032 Index 003
Part.-No. 01013399-GB (EU-BD 783)