ZIEHL-ABEGG R-E-1.5G Operating Instructions Manual Download Page 3

1 General notes

1.1 Structure of the operating instructions

Before installation and start-up, read this manual carefully to ensure correct use!
We emphasize that these operating instructions apply to speci

c units only, and are in 

no way valid for the complete system!
Use these operating instructions to work safely with and on the device. They contain 
safety instructions that must be complied with as well as information that is required for 
failure-free operation of the device.
Keep these operating instructions together with the device. It must be ensured that all 
persons that are to work on the device can refer to the operating instructions at any time.

1.2 Exclusion of liability

To allow for future developments, construction methods and technical data given are 
subject to alteration. We do not accept any liability for possible errors or omissions in the 
information contained in data, illustrations or drawings provided.
We accept no liability for damage caused by misuse, incorrect use, improper use or as a 
consequence of unauthorized repairs or modi

cations.

2 Safety instructions

Installation, electrical connection and commissioning to be carried out by trained 
service personnel only. The speci

cations of the manufacturer or supplier, and 

instructions relating to the equipment, should be rigidly adhered to. Failure to comply 
with these conditions will invalidate the guarantee on our controllers and accessories!

The 5 electrical safety rules must be observed!

It is strictly forbidden for work to be carried out on any components while they are 
connected to live voltage. The open equipment is protected to IP00. It is possible to 
come into direct contact with dangerous voltages!

The safe isolation from the supply must be checked using a 

two-pole

 voltage 

detector. 

Cover neighbouring electrical equipment during installation work.

During operation, the device must be closed or installed in a control cabinet. Fuses 
may only be replaced by new ones and must not be repaired or bypassed. The data 
for the maximum line fuse are to be considered absolutely (see Technical data). Use 
only fuses speci

ed in schematic diagrams.

Never clean electrical equipment with water or similar liquids.

The equipment is to be used solely for the purposes speci

ed and con

rmed in the 

order. Other uses which do not coincide with, or which exceed those speci

ed will be 

deemed unauthorised unless contractually agreed. Damages resulting from such 
unauthorised uses will not be the liability of the manufacturer. The user will assume 
sole liability.

During commissioning, unexpected and hazardous conditions can arise in the entire 
installation due to defective adjustments, defective components or incorrect electrical 
connections. Remove all persons and objects from the hazardous area.

Operating Instructions 

R-E-1.5...14G, RUE-2...7.5G

General notes

L-BAL-E191-GB 1735 Index 003

Part.-No. 

3/12

Summary of Contents for R-E-1.5G

Page 1: ... 5 14G RUE 2 7 5G Transformer based controllers for variable voltage 1 motors Operating Instructions Keep for reference L BAL E191 GB 1735 Index 003 Part No english D GB DK E F I PL RU S www ziehl abegg com ...

Page 2: ... 5 3 1 Function 5 3 2 Maintenance 5 3 3 Transport 5 3 4 Storage 5 3 5 Disposal recycling 6 4 Installation 6 4 1 General notes 6 4 2 Minimum space requirement 7 4 3 Mains connection 7 4 4 Motor connection 7 5 Enclosure 8 5 1 Technical data 8 5 2 Connection diagram 9 5 3 Dimensions mm 11 5 4 Manufacturer reference 12 5 5 Service information 12 Operating Instructions R E 1 5 14G RUE 2 7 5G L BAL E191...

Page 3: ...y with these conditions will invalidate the guarantee on our controllers and accessories The 5 electrical safety rules must be observed It is strictly forbidden for work to be carried out on any components while they are connected to live voltage The open equipment is protected to IP00 It is possible to come into direct contact with dangerous voltages The safe isolation from the supply must be che...

Page 4: ...anations of symbols Safety instructions are highlighted with warning triangles and are depicted according to the degree of hazard as follows Attention General hazardous area Death or severe injury or significant property damage can occur if the corresponding precautions are not taken Danger due to electric current Danger by dangerous electric voltage Death or severe injury can occur if the correspo...

Page 5: ...ional voltage output 230 V terminal L 1 is activated if fan runs at steps 1 2 3 4 or 5 It could be used e g for a signal lamp or damper control maximum load see connection diagram Attention Automatically restart after a power failure or mains disconnection 3 2 Maintenance The device must be checked for soiling and if necessary cleaned in periodic intervals 3 3 Transport The device is packed ex fac...

Page 6: ...e appropriate mounting devices for proper installation of the unit Do not mount equipment on vibrating base Do not allow drilling chips screws and other foreign bodies to reach the device interior The device should be installed in a location where it will not be disturbed but at the same time can be easily accessed Depending on the housing model use supplied stoppers for cable inlets cut off neces...

Page 7: ... technical data and rating plate affixed to the side The mains voltage must comply with the EN 50160 quality characteristics and the defined standard voltages in IEC 60038 Danger due to electric current The integrated autotransformer is not short circuit proof it is essential to note the size of the internal fuse and the maximum prefuse see technical data 4 4 Motor connection The motor leads are con...

Page 8: ...ion R E 1 5G 302001 1 5 T 4 20 1 74 IP54 R E 2G 302107 2 0 16 T 4 20 2 1 IP54 R E 3 5G 302108 3 5 16 T 4 30 3 5 IP54 R E 6G 302109 6 0 16 T 8 35 4 9 IP54 R E 7 5G 302053 7 5 T 8 40 6 0 IP54 R E 9G 302055 9 0 T 16 50 10 5 IP54 R E 12 302056 12 0 T 20 80 9 1 IP21 R E 14G 302057 14 0 T 20 105 12 5 IP54 RUE 2G 302063 2 0 T 4 25 3 55 IP54 RUE 4G 302064 4 0 T 6 35 4 8 IP54 RUE 7 5G 302065 7 5 T 8 45 6 3...

Page 9: ... AC 230 V 1 A N L 3 1 RENT05K2 06 09 2016 R E 2 3 5 6G N L1 PE L1 N U1 U2 N L M 1 U1 U2 PE Kontaktbelastung Contact rating max AC 230 V 1 A Netz Line 1 230 V 50 60 Hz 1 Motor ohne Thermostatschalter without thermostats 1 2 3 L PE PE 1 Line 1 230 V 50 60 Hz 2 1 motor without thermostats 3 Contact rating 230 V AC max 1 A Operating Instructions R E 1 5 14G RUE 2 7 5G Enclosure L BAL E191 GB 1735 Inde...

Page 10: ...thermostats 2 U1 U2 1 2 Kontaktbelastung Contact rating max AC 230 V 1 A N L 3 1 4 3 4 5 6 7 A B Schaltuhr Time switch AC 230 V 1 Line 1 230 V 50 60 Hz 2 1 motor without thermostats 3 Contact rating 230 V AC max 1 A 4 Time switch Operating Instructions R E 1 5 14G RUE 2 7 5G Enclosure L BAL E191 GB 1735 Index 003 Part No 10 12 ...

Page 11: ...5 3 Dimensions mm R E 1 5G R E 2 3 5 6G RUE 2 4 7 5G R E 7 5G R E 9 12 14G Operating Instructions R E 1 5 14G RUE 2 7 5G Enclosure L BAL E191 GB 1735 Index 003 Part No 11 12 ...

Page 12: ... our technical support for control systems ventilation technology phone 49 0 7940 16 800 Email fan controls service ziehl abegg de Our worldwide contacts are available in our subsidiaries for deliveries outside of Ger many see www ziehl abegg com If you make returns for inspections or repairs we need certain information in order to facilitate focused trouble shooting and fast repair Please use our...