background image

4 Mounting

4.1 General notes

Attention!

Check the fan for damage, e.g. cracks, dents or damage to the electric cables, before 
assembly. Start-up is not allowed in the case of transport damage!

Mounting is only to be undertaken by trained service personnel. The system 
manufacturer or the machine builder and/or the user is responsible that the inherent 
installation and security information are harmonized with the valid standard and 
guidelines (EN ISO12100 / 13857).

Do not allow drilling chips, screws and other foreign bodies to reach the device 
interior!

Prior to installing the fan, it is to be checked whether the safety zone as per EN ISO 
13857 and in household appliances as per EN 60335 are met. If the installation height 
(danger zone) above the reference level is greater than or equal to 2700 mm and is 
not reduced by auxiliary means such as chairs, ladders, work platforms or bases on 
vehicles, a guard grille against accidental contact is not necessary at the fan.

If the fan is located in danger zone, then the manufacturer or operator shall ensure 
that hazards shall be prevented by appropriare protective constuctions which meet 
the requirements to EN ISO 13857. 

The custom designs must suit the prevailing conditions.

Tighten the fastenings with the speci

ed torques.

Any use below -10 

°

C is dependent on not being subjected to unusual, sudden or 

mechanical loads or stresses on the material (min. ambient temperature 

  Technical 

data). 

Corrosion is possible at the cutting edges on sendzimir galvanised parts. 

The chemical after-treatment of the nozzle can lead to visible residues. These do not 
have any technical e

ect however.

4.2 Connection cable & junction box

Info

In demanding environments (wet rooms, outdoor installation), connection cables must 
have water draining pipe elbows. If using a junction box, install this lower than the motor 
to ensure that water cannot penetrate through to the controller housing from the 
connection cables.

Assembly instructions 

FE2owlet-ECQ

Mounting

L-BAL-F062-GB 2022/20 Index 004

Part.-No. 00702389-GB

11/24

Summary of Contents for FE2owlet-ECQ

Page 1: ...FE2owlet ECQ Motor size U EC fans with top ef ciency Assembly instructions Keep for reference L BAL F062 GB 2022 20 Index 004 Part No 00702389 GB english...

Page 2: ...e 7 2 8 Operator s obligation of diligence 8 2 9 Employment of external personnel 8 3 Product overview 9 3 1 Application operational area 9 3 2 Functional description 9 3 3 Motor protection 9 3 4 Note...

Page 3: ...servicing 17 7 2 Cleaning 18 8 Enclosure 18 8 1 Technical data 18 8 2 EC Declaration of Incorporation 20 8 3 UKCA Declaration of Incorporation 22 8 4 Manufacturer 24 8 5 Service address 24 Assembly i...

Page 4: ...its only and are in no way valid for the complete system Use these assembly instructions to work safely with and on the device They contain safety instructions that must be complied with as well as in...

Page 5: ...contained instructions especially the safety noti cations contained therein are considered part of intended use To consider is also the documentation of attached components 2 2 Improper use Improper...

Page 6: ...voltage Death or severe injury can occur if the corresponding precautions are not taken Info Important additional information and advice for user 2 4 Product safety The device conforms to the state of...

Page 7: ...m the supply must be checked using a two pole voltage detector Opening of motor is prohibited Loosening the screws will void the warranty Any faults detected in the electric system modules operating e...

Page 8: ...ons and or operating instructions are always readily available at the location where the device is being used are complete and are in legible condition These persons are regularly instructed in all ap...

Page 9: ...hree speeds rating plate Motors with three speeds Three pre programmed speeds are possible rating plate which are activated depending on the connection of the additional control input at L1 or N With...

Page 10: ...nical Data Pay attention to possible damage of the packaging or the equipment Store the fan motor in the original packaging in a dry area protected from the weather and protect it from dirt and weathe...

Page 11: ...ccidental contact is not necessary at the fan If the fan is located in danger zone then the manufacturer or operator shall ensure that hazards shall be prevented by appropriare protective constuctions...

Page 12: ...Permissible tightening torques MA Fastening element Central screw connec tion Fastening element for add on parts Motor fastening Material Steel Steel Plastic Motor size U Thread size M4 Property class...

Page 13: ...ation surfaces must be level 4 5 Connection of the motor Danger due to electric current The mains voltage must comply with the EN 50160 quality characteristics and the de ned standard voltages in IEC...

Page 14: ...h the brown wire the motor runs at speed step 3 If the black wire is connected with the blue wire the motor runs at speed step 2 If the black wire is not connected the motor runs at speed step 1 Dange...

Page 15: ...y closed according to the suitable installation position 6 Connection data complies with the speci cations on the rating plate During start up check the following 1 Check the rotat direction see the r...

Page 16: ...irection Motor turns in wrong direc tion at high speed Check air stream see Fan does not run Fan turns too slowly Impeller blade drags scrapes When indicated clear foreign bodies dirt from the fan Che...

Page 17: ...maintenance work at running fan Watch out for vibration free motion The impeller is subject to natural wear depending on the area of application and the conveying medium Deposits on the impeller can...

Page 18: ...ity for the standard volt age 230 400 V according to IEC 60038 Interference emission according to EN 55014 1 do mestic household applications Interference immunity according to EN 61000 4 4 in dustria...

Page 19: ...004 7 Electronically Protected Motor Component For motors with three speeds and corresponding quality mark rating plate Authorization FILE No E123518 UL 1004 3 Thermal device protected Motor Component...

Page 20: ...Machinery Directive 2006 42 EC Manufacturer ZIEHL ABEGG SE Heinz Ziehl Stra e 74653 K nzelsau Germany The following harmonized standards have been applied EN 60204 1 2018 Safety of machinery Electric...

Page 21: ...turer Start up of this incomplete machine is prohibited until it is ensured that the machine in which it has been installed complies with the provisions of the EC Machinery Directive K nzelsau 27 04 2...

Page 22: ...hinery Safety Regulations 2008 No 1597 The manufacturer is ZIEHL ABEGG SE Heinz Ziehl Stra e D 74653 K nzelsau The following harmonised standards have been used EN 60204 1 2018 Safety of machinery ele...

Page 23: ...It is prohibited to commission this incomplete machine until it has been secured that the machine into which it was incorporated complies with the stipulations of the Machinery Safety Regulations K nz...

Page 24: ...you are planning special applications please contact ZIEHL ABEGG SE Heinz Ziehl Stra e D 74653 K nzelsau Phone 07940 16 0 Fax 07940 16 300 info ziehl abegg de 8 5 Service address Please refer to the h...

Reviews: