3 General description

3.1 Operational area

The add-on module can only be used together with compatible Ziehl-Abegg devices.

3.2 Function

ECblue fans with integrated auxiliary module AM-LON offer the following func-
tions:

The 

AM-LON

 module can be used to communicate with the controller of the fan.

ECblue fans can be integrated into existing LON

®

 networks.

A LON

®

 network of several ECblue fans can be built up. The communication 

between the fans happens via LONWORKS

®

 FT10.

Networkk interface description 

  R-TIL11_01-GB.

3.3 Transport

The device is packed ex factory to suit the transport method previously agreed.

Always use the original packaging materials when transporting the device.

Avoid shocks and impacts to the device during the transport.

During manual handling the human lifting and carrying restrictions must be 
observed and adhered to.

3.4 Storage

The device must be stored in its original packaging in a dry and weather-proof 
room.

Avoid exposure to extreme heat and cold.

Avoid over-long storage periods (we recommend a maximum of one year).

3.5 Disposal / recycling

Disposal must be carried out professionally and in an environmentally friendly way in 
accordance with the respective national legal stipulations.

Separate the materials by type and in an environmentally friendly way.

If necessary, commission a specialist company with the waste disposal.

Operating Instructions 

AM-LON

 

General description

L-BAL-E166-GB 1610 Index 002

Part.-No. 00163375-GB

4/9

Summary of Contents for AM-LON

Page 1: ...AM LON Part No 349049 Communication module for ECblue fans Operating Instructions L BAL E166 GB 1610 Index 002 Part No 00163375 GB english ...

Page 2: ... 3 5 Disposal recycling 4 4 Mounting the module 5 5 Electrical installation 6 5 1 Safety precautions 6 5 2 Voltage supply 6 5 3 Communication 6 5 3 1 Connecting at the AM LON Modul 6 5 3 2 Wiring and terminating resistor in the LON network 7 6 Enclosure 8 6 1 Connection diagram 8 6 2 Manufacturer reference 9 6 3 Service information 9 Operating Instructions AM LON L BAL E166 GB 1610 Index 002 Part ...

Page 3: ... electrical connection and start up operation may only be carried out by an electrical specialist in accordance with electrotechnical regulations e g EN 50110 or EN 60204 Danger due to electric current It is generally forbidden to carry out work on electrical live parts Protection class of the device when open is IP00 It is possible to touch hazardous voltages directly The 5 electrical safety rule...

Page 4: ...inal packaging materials when transporting the device Avoid shocks and impacts to the device during the transport During manual handling the human lifting and carrying restrictions must be observed and adhered to 3 4 Storage The device must be stored in its original packaging in a dry and weather proof room Avoid exposure to extreme heat and cold Avoid over long storage periods we recommend a maxi...

Page 5: ...ing This applies regardless of whether the device is already connected to the line Equalize the potential again shortly before installation if the module is not installed immediately after unpacking After unpacking the module check for possible transport damage and insert it in the slot provided Do not touch the connection ECblue Mount the module in the housing with the two enclosed screws permiss...

Page 6: ...ected to terminals NET_A and NET_B The correct choice of cable is essential for the proper operation of the network Recommended wire types 22AWG twisted pair typical solid an unshilded Remote control line JY St Y 2x2x0 6 Wieland line system gesis con The connection of the LON bus is not polarity sensitive When using cable with more than two strands ensure that two twisted strands only are used for...

Page 7: ...e for routing reasons then free wiring can be used as an alternative Please note the restrictions on line length Information If any matters are unclear you can send for our technical information sheet Network structure of a LON TIL00_70 It contains information about the topology circuitry and selection of types of cable With free wiring i e no wiring rule is applied a terminating resistor of 50 Ω ...

Page 8: ...6 1 Connection diagram AM LON ID1 V ID2 MOLN07K0 15 03 2011 LON Service Pin max 5 VDC V LON Service Pin max 5 VDC B A B A Operating Instructions AM LON Enclosure L BAL E166 GB 1610 Index 002 Part No 00163375 GB 8 9 ...

Page 9: ...for control systems ventilation technology phone 49 0 7940 16 800 Email fan controls service ziehl abegg de Our worldwide contacts are available in our subsidiaries for deliveries outside of Ger many www ziehl abegg com If you make returns for inspections or repairs we need certain information in order to facilitate focused trouble shooting and fast repair Please use our repair tickets for this It...

Reviews: