Set the function selector switch to "F"
Connect the (discharged!) device under test socket " " and
"F" with measurement leads. Polarized capacitors must be
connected to the " " socket at the " -- " pole.
electrically dead. External voltages would falsify the
measurement results!
The resistance measured at the moment the REL key is
pressed serves as a reference value. This value is then
automatically subtracted from all measured value.
Deleting Zero Adjustment
Short the leads connected to meter and then press REL key.
or Activate the function selector switch.
or Switch the Multimeter off.
0
C
Resistors and semiconductor paths in parallel to
the capacitor falsify the measurement results!
To measure small value capacitors please use
short measurement cables!
If is displayed the measured values are not valid.
Be absolutely certain that the device under test is