Zico ZI-2090 Instruction Manual Download Page 12

 

12 

master-testing unit. 

4. Once both ends of the cable are plugged in properly, the 

second  row  of  LEDs  will  illuminate  according  to  the 
corresponding LEDs in the top row. 

5.  Read  the  results  of  the  LED  display  for  the  pin 

configuration status of the tested cable. If you fail to read 
the results the first time in Auto mode, you may wait for the 
second LED scan, or simply switch to Manual mode for pin 
by pin testing. In Manual mode, pressing the square "Test" 
button will advance testing to the next pin. 

 

RJ11 Modular Cable Test 

Please follow directions for the UTP/STP Cable Test anduse 
the operations manual for the correct LED pin out display 

 
Coaxial Cable Test 

1.Plug the two attached BNC adapter cables on both RJ45 

jacks. Then connect the tested cable to each end of the 
BNC adapter cables 

2.    For  the  remaining  testing  procedures,  please  refer  to 

10Base-T Test    steps 2 to 5. 

Note: 

1. The center pin of BNC should be read on LED 2. 
2. As Coaxial cable has only two wires, we suggest you read 

the result of the LED scan using Manual mode. 

   

Remote Test 

1. Plug one end of the tested cable to the transmitting RJ45 

jack on the master unit marked with a ' ' and plug the other 
end  into  the  remote  terminator.  If  the  tested  cable  is 
installed  in  a  patch  panel  or  wall  plate,  you  may  use  the 
included  patch  cable  to  solve  the  connector  gender 
problem. 

Summary of Contents for ZI-2090

Page 1: ...1 ZI 2090 Instruction Manual 2in1 LAN Tester Multimeter www zicotech com...

Page 2: ...ther at a wall jack or a patch panel adding up to value and convenience Proper use and care of this meter will provide years of reliable service Features 2in1 LAN Tester Multimeter Measures DC AC Volt...

Page 3: ...further information This symbol adjacent to a terminal indicates that under normal use hazardous voltages may be present Double insulation Safety Precautions 1 Improper use of this meter can cause da...

Page 4: ...care when making measurements if the voltages are greater than 25VAC rms or 35VDC These voltages are considered a shock hazard 6 Always discharge capacitors and remove power from the device under test...

Page 5: ...splay for receiving end Jack 2 7 Test switch for auto scan 8 LAN tester Power switch 9 Test switch for manual scan Digital multimeter part Description 10 17 10 Function switch 11 3 1 2 Digit 2000 coun...

Page 6: ...0mA 200 0mA 2 0 rdg 3d AC Current 200 0 A 2000 A 1 8 rdg 8d 20 00mA 200 0mA 2 5 rdg 8d Resistance 200 0 0 8 rdg 5d 2 000k 20 00k 200 0k 1 2 rdg 3d 2 000M 2 0 rdg 5d 20 00M 5 0 rdg 8d Max input voltage...

Page 7: ...ure 14 o F to 122 o F 10 o C to 50 o C Weight 308g Size 162x74 5x44 0mm Standard IEC61010 1 CAT III 600V Pollution degree II CE Approved Operation AC DC VOLTAGE MEASUREMENTS CAUTION Do not measure AC...

Page 8: ...ack test probe tip to the negative side of the circuit Touch the red test probe tip to the positive side of the circuit 7 Apply power to the circuit 8 Read the current in the display RESISTANCE MEASUR...

Page 9: ...e positive terminal 3 on the display 4 Touch the test probe tips to the circuit or wire you wish to check 5 If the resistance is less than approximately 150 the audible signal will sound If the circui...

Page 10: ...HOLD button to freeze the display the HOLD indicator will appear 2 Press the DATA HOLD button to return to normal operation AUTO POWER OFF The auto off feature will turn the meter off after 15 minutes...

Page 11: ...place 9 Replace and secure the rear cover battery and battery cover Multi Network Modular Cable Tester Operation Note Make sure the battery power is sufficient Insufficient battery power will lead to...

Page 12: ...able Test anduse the operations manual for the correct LED pin out display Coaxial Cable Test 1 Plug the two attached BNC adapter cables on both RJ45 jacks Then connect the tested cable to each end of...

Page 13: ...ing end of the master unit Sample Test Results 1 2 3 4 5 6 7 8 G 1 Continuity Pin 2 has continuity 1 2 3 4 5 6 7 8 G 2 Open Pin 2 is opened 1 2 3 4 5 6 7 8 G 3 Short Pin 2 and Pin 3 are shorted 1 2 3...

Reviews: