background image

the set temperature by 3°C. Subsequently, when the room temperature has dropped

again to the set temperature, the heater will automatically switch on again.  Activate

the 'SAVE' setting by pressing the appropriate 

Q

key. The SAVE indicator light will

light up (Fig. J). Switch off the function by pressing the SAVE key once again.

Without the 'SAVE' setting your heater will maintain the set temperature by

approximation as well, by adjusting its heating capacity. 'SAVE' is an economy

setting, which you can use when, for instance, you are not present in the room

or to keep it frost-free.

K

THE 'FUEL' INDICATOR LIGHT

When the indicator light FUEL lights up, it means that there is only fuel left for 10

more minutes. The count-down of the remaining heating time can be seen in the

information display 

(Fig. K). Now you have two options:

E

you remove the fuel tank and refill it outside the living room (section B) or

E

you push the button EXTENSION 

S

. By pushing this button, the remaining 

heating time will extend to 90 minutes. The heater will automatically switch 

back to its lowest position. In the display the number 90 will appear, which 

will decline to 10. At the arrival of 10, you will hear an alarmsignal every two 

minutes, warning you to refill the removable tank. If you do not react, the 

heater will extinguish by itself. The heater will also sound a warning signal, 

when it switches off. The fuel indicator light will blink, while four lines (--:--) 

are blinking in the information display. You can stop this by pressing the 

button 

once more.

Once the heater has used up all its fuel and extinguished, it will take some time,

after the refill, before the heater is completely ready for use again.

L

THE 'VENT' INDICATOR LIGHT

When there is insufficient ventilation in the room, an intermittent buzzer will be

heard (approximately once each 30 seconds) and the VENT indicator will be lit.

When this signal is given, ensure that the ventilation of the room is improved (e.g.

by opening a door or window a little more), to avoid that the heater shuts off.

When the ventilation of the room is improved, the VENT indicator and buzzer will

be deactivated. When there is still insufficient ventilation, the heater shuts off

automatically. When this occurs, 

e -1 1

is displayed and the VENT indicator is

blinking. After improving the ventilation of the room (e.g. by opening a door or

window a little more), the heater can be ignited by pushing  

M

again. 

If the indicator light continues blinking after extra ventilation, please contact your

Zibro dealer.

M

MAINTENANCE

Switch off the heater and let it cool down, before you start any maintenance

work. Also disconnect the plug from the mains. Your Zibro needs hardly any

maintenance. It is, however, important that you clean the air filter 

8

and the vent

filter 

9

with a vacuum cleaner and the grid 

with a damp cloth, both on a

weekly basis. Remove the air filter cap occasionally (Fig. M) and clean it with soapy

water. Prior to reinstallation, make sure that the air filter cap has fully dried. 

Regularly inspect the fuel filter as well:

4

57

L: A blinking VENT

indicator light is a sign

that you need extra

ventilation.

K: When the FUEL

indicator light is lit, the

information display will

show the number of

minutes of fuel left in 

the tank.

J: When the SAVE light

lights up, the heater will

automatically switch on

or off in order to remain

within a specified

temperature range.

M

Summary of Contents for SRE 168 E

Page 1: ...2 6 5 4 u 1 FIN MANUEL D UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO KÄYTTÖOHJE OPERATING MANUAL ISTRUZIONI D USO BRUKSANVISNING GEBRUIKSAANWIJZING BRUKSANVISNING 2 10 20 30 40 50 60 70 80 90 ...

Page 2: ...se read these Directions for Use first to ensure maximum lifetime for your Zibro Your heater comes with a 24 month manufacturer s warranty on all defects in material or workmanship We wish you much warmth and comfort with your Zibro Yours sincerely PVG International b v Customer Service Department 1 READ THE DIRECTIONS FOR USE FIRST 2 IN CASE OF ANY DOUBT CONTACT YOUR ZIBRO DEALER 3 BEFORE YOU STA...

Page 3: ...ning fuel in the heater MAIN COMPONENTS Front plate Grid Base plate Lid for removable tank Operation panel Handle Removable tank Air filter Vent filter Thermostat Plug cord Information display key Childproof lock Adjustment keys time and temperature TIMER SAVE key Indicator lights EXTENSION Connection weektimer Air quality control system A B C 4 E F G H I J K L M N O P Q R S T E E E E E E E E E E ...

Page 4: ... your Zibro in cellars or other underground areas THE RIGHT FUEL Only use Class C1 paraffin fuel in accordance with BS2869 Part 2 or equivalent Your Zibro heater has been designed for use with high quality water free pure paraffin oil such as Zibro Extra or Zibro Kristal Only fuels of this kind will ensure clean and proper burning Lower quality fuel may result in E increased possibility of malfunc...

Page 5: ... O refer to Section C Your Zibro is now ready for use B FILLING FUEL Do not fill the removable tank in the living room but in a more suitable place there can always be some spillage Follow the procedure below Make sure that the heater is switched off Open the lid 4 and lift the removable tank 7 out of the heater Fig B Note Some drops may leak from the tank Put down the removable tank cap pointing ...

Page 6: ...inutes or after a power failure the time needs to be set again D IGNITING THE HEATER When used for the first time a new heater may give out a smell for a short while You should therefore provide extra ventilation Always ignite the heater with the button M Never use matches or a cigarette lighter Just press the button M to ignite the heater The button will start blinking indicating that the ignitio...

Page 7: ...approximately the required temperature at the set time When you want to switch off the heater and ignite it again with the timer all you have to do is press the TIMER key refer to Section G Press the button M once to clear the timer setting If you would like more extensive timer possibilities we advise you to procure the Zibro weektimer This timer is easy to connect with your Zibro Heater see T G ...

Page 8: ...heater has been burning continuously for two hours at its highest setting the burner will automatically start an autoclean procedure The display will show the autocleaning code cl 05 running back to cl 01 The procedure takes 5 minutes during which the heater will burn at its lowest setting while the burner autocleans When the burner is clean again the heater will automatically switch back to the h...

Page 9: ...ll take some time after the refill before the heater is completely ready for use again L THE VENT INDICATOR LIGHT When there is insufficient ventilation in the room an intermittent buzzer will be heard approximately once each 30 seconds and the VENT indicator will be lit When this signal is given ensure that the ventilation of the room is improved e g by opening a door or window a little more to a...

Page 10: ...el When you start re using the heater follow the instructions again starting from section A and as specified O TRANSPORTATION Take the following measures to avoid fuel leakage during the transportation of the heater Let the heater cool down Remove the removable tank G from the heater and remove the fuel filter refer to Section M Fig N Some drops may leak from the filter keep a cloth at hand Store ...

Page 11: ...nces may induce uncontrollable burning causing flames to break out Should this happen never try to move the heater but always switch off the heater immediately In case of emergency you may use a fire extinguisher but only a type B extinguisher a carbon dioxide or powder extinguisher 10 TIPS FOR SAFE USE 1 Make sure that children are always aware of the presence of a burning heater 2 Do not move th...

Page 12: ...s produits de combustion Contrôle de la qualité de la combustion absence de CO Endurance Intermittence CONSEILS D UTILISATION ET D ENTRETIEN Se reporter à la notice jointe à l appareil et à la plaque de sécurité sur l appareil Référence et numéro de lot ou de série de l article se reporter au produit Distributed in Europe by PVG International B V P O Box 96 5340 AB OSS Pays Bas Tél 31 0 412 694670...

Page 13: ...E E E E E E E E E E E E E E E E E E E E E E E E E A E G F D J B C I K H E Q P S N L R M T O ...

Page 14: ...ce zibro com SUOMI Appliance Finland Oy Piispantilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com F FI IN N 4 UNITED KINGDOM Scott Brothers Ltd The Old Barn Holly House Estate Cranage Middlewich CW10 9LT UK tel 44 1606 837787 fax 44 1606 837757 email sales scottmail co uk ITALIA PVG Italy SRL Via Niccolò Copernico 5 50051 CASTELFIORENTINO FI tel 39 ...

Reviews: