Zibro Laser FF 55 Operating Instructions Manual Download Page 24

P

V

G

T

ra

ff

ic

a

v

g

©

0

7

0

7

2

0

m

a

n

_

L

a

se

r

F

F

5

5

Rev. 9/07

DISTRIBUTED IN EUROPE BY PVG INTERNATIONAL b.v.

i

ÖSTERREICH

PVG Austria VertriebsgmbH
Salaberg 49
3350 HAAG
tel:

+43 7434 44867

fax: 

+43 7434 44868

email:     [email protected]

e

BELGIË

PVG Belgium NV/SA
Industrielaan 55
2900 SCHOTEN
tel: 

+32 3 326 39 39

fax: 

+32 3 326 26 39

email:

[email protected]

q

SCHWEIZ

PVG Schweiz AG
Salinenstrasse 63
4133 PRATTELN
tel:

+41 61 337 26 51

fax:

+41 61 337 26 78

email:

[email protected]

2

DEUTSCHLAND

PVG Deutschland GmbH
Siemensstrasse 31
47533 KLEVE
tel: 

0800 - 9427646

fax: 

+31 (0)412 648 385 

email:

[email protected]

6

DANMARK

Appliance A/S
Blovstroed Teglvaerksvej 3
DK-3450 ALLEROED
tel: 

+45 70 205 701

fax: 

+45 70 208 701

email:

[email protected]

5

ESPAÑA

PVG España S.A.
Pol. Ind. San José de Valderas II
Comunidad ”La Alameda”
C/ Aurora Boreal, 19
28918 LEGANÉS (Madrid)
tel: 

+34 91 611 31 13

fax: 

+34 91 612 73 04

email:

[email protected]

3

FRANCE

PVG France SARL
4, Rue Jean Sibélius
B.P. 185
76410  SOTTEVILLE SOUS LE VAL
tel: 

+33 2 32 96 07 47

fax: 

+33 0 820 34 64 84

email:

[email protected]

SUOMI

Appliance Finland Oy
Piispantilankuja 6C
02240 ESPOO
tel: 

+358 9 4390 030

fax: 

+358 9 4390 0320

email:

[email protected]

F

FIIN

N

4

UNITED KINGDOM

Scott Brothers Ltd.
The Old Barn, Holly House Estate
Cranage, Middlewich, CW10 9LT UK
tel.: 

+44 1606 837787

fax: 

+44 1606 837757

email: [email protected]

>

ITALIA

PVG Italy SRL
Via Niccolò Copernico 5
50051 CASTELFIORENTINO (FI)
tel: 

+39 571 628 500

fax: 

+39 571 628 504

email:

[email protected]

u

NORGE

Appliance Norge AS
Vogellunden 31
1394 NESBRU
tel: 

+47 667 76 200

fax: 

+47 667 76 201

email:

[email protected]

1

NEDERLAND

PVG International B.V.
P.O. Box 96
5340 AB OSS
tel: 

+31 412 694 694

fax: 

+31 412 622 893

email:

[email protected]

9

PORTUGAL

Gardena, Lda
Recta da Granja do Marquês
ALGUEIRÃO 
2725-596  MEM MARTINS
tel:

+ 35 21 92 28 530

fax:

+ 35 21 92 28 536

email:

[email protected]

:

POLSKA

PVG Polska Sp. z. o. o.
ul. Ko

ś

cielna 110

26-800 Bia

ł

obrzegi

tel: 

+48 48 613 00 70

fax: 

+48 48 613 00 70

email:

[email protected]

=

SVERIGE

Appliance Sweden AB
Sjögatan 6
25225 HELSINGBORG
tel: 

+46 42 287 830

fax: 

+46 42 145 890

email:

[email protected]

TURKEY

PVG Is›tma Klima So¤utma Ltd.fiti. 
Atatürk Cad. No 380 Ak Iflhani Kat 6
35220 Alsancak 

IZMIR - TURKEY
tel:

+ 90 232 463 33 72

fax:

+ 90 232 463 69 91 

email:

[email protected]

T

TR

R

Printed in Japan

7145002060

Summary of Contents for Laser FF 55

Page 1: ...Laser FF 55 2 24 46 68 MANUEL D UTILISATION OPERATING INSTRUCTIONS GEBRUIKSAANWIJZING KULLANIM KILAVUZU 3 4 1 TR...

Page 2: ...urse provided you use the heater correctly Please read these Directions for Use first to ensure maximum lifetime for your Zibro Your heater comes with a 24 month manufacturer s warranty on all defects...

Page 3: ...25 SUMMARY Chapter 1 INSTALLATION Chapter 2 OPERATION Chapter 3 ERROR MASSAGES Chapter 4 WARRANTY PROVISIONS...

Page 4: ...re you leave or go sleeping Unplug the heater as well when you go away for a longer period of time e g holidays 5 Store and move fuel only in suitable tanks and jerrycans 6 Make sure that the fuel is...

Page 5: ...n We recom mend that you store fuel elsewhere The Laser System can be placed on any type of flooring including fitted carpets or other flammable materials and operate safely unless fuel or fire safety...

Page 6: ...ons 5 Unpacking Save all packaging materials for possible future trans portation A Remove the cardboard drilling template and the user s manual from the packaging B Remove the box with the installatio...

Page 7: ...cm Not less than 45 cm Not less than 45 cm Frontal obstruction 45 cm or more 50 cm or more Snow covered surface or ground Important The gap with the ground must be enlarged in areas subject to heavy s...

Page 8: ...se are the dimensions and locations of the holes for the fuel pipe and exhaust pipe Do not remove any components from the heater Always contact your dealer if repairs are required If the electricity c...

Page 9: ...rts The following list of standard installation parts is sup plied with your heater It may be necessary to order extra parts from your Zibro dealer if other installation methods are required Wall hook...

Page 10: ...Chapter 1 INSTALLATION 32 Right angled exhaust pipe bend 1 Right angled air hose 2 Flexible air hose 1 Hose clip 2 Manual fuel pump 1 Fuel cap cover 1...

Page 11: ...heater can be levelled by means of adjustable legs This can be checked with the plumb line 2 Drill the hole for the exhaust pipe Use a hole saw with a diameter of 70 80 mm see Fig 5 The opening on the...

Page 12: ...Install the inner flue pipe a For wall thickness 230 320mm From inside the room insert the inner flue pipe through the hole Make sure the arrow on the inner flue pipe is pointing up Secure the inner f...

Page 13: ...ose to the inlet of the exhaust pipe Fasten the right angled air hose onto the inlet with a hose clip Seal the inlets and outlets that are not being used with the caps supplied Check that the caps are...

Page 14: ...re tight See Fig 11 Fig 11 6 Fasten the right angled air hose to the inlet with the hose clip Attach the right angled exhaust bend to the exhaust pipe with the pipe holder If the extension pipe is use...

Page 15: ...hat the airflow to the air circulation ventilator is not obstructed Inspect the interior of the building to ensure that the area immediately adjacent to the heater is free of fuel and objects that may...

Page 16: ...em All specified operating procedures must be carried out in the order in which they are described 2 Laser FF 55 heater specifications Nominal yield as applied to petroleum heaters 92 7 Power consumpt...

Page 17: ...imit the temperature When this function is activated the heater will automatically switch off and on again 5 TIMER button Allows you to switch on the heater automatically at a preset time 6 CHILDPROOF...

Page 18: ...longer 6 Check the removable tank fuel gauge while filling the tank Stop filling by loosening the switch button on top of the pump turn anti clockwise once the gauge indicates that the tank is full Ne...

Page 19: ...d the button on the left c hour to lower the temperature Press once to increase the value one step After approximately 10 seconds the light will stop blinking and setting will be locked The available...

Page 20: ...rm air flowing out of the heater 8 Childproof lock The childproof lock can be used to prevent children accidentally changing the heater settings When the heater is burning and the childproof lock is o...

Page 21: ...ace Never clean it with water 3 Reinstall the fuel filter into the heater We recommend that you remove dust and stains in time with a damp cloth because otherwise these may cause stains that are hard...

Page 22: ...he air filter and remove dust E 13 Burner thermistor malfunction Contact your dealer Excess fuel in the burner Contact your dealer E 22 Ignition failure three times Contact your dealer No fuel Refill...

Page 23: ...mages caused by actions not in compliance with the Directions for Use neglect and the use of an incorrect type of fuel or fuel past its use by date The use of incorret fuel can even be dangerous Trans...

Page 24: ...Finland Oy Piispantilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com F FI IN N 4 UNITED KINGDOM Scott Brothers Ltd The Old Barn Holly House Estate Cra...

Reviews: