96
Chapter 3, ERROR MESSAGES
Error code
Problem
Cause
Solution
Power light is not lit.
The plug is not in the socket.
Insert the plug into the socket.
The print plate does not function
Check the fuse or contact your
correctly.
dealer.
EE2
No ignition.
No fuel.
Check fuel meter, top up if necessary.
The fuel tank valve is closed.
Open the valve by turning it
anticlockwise.
Air bubble in the fuel pipe.
Press the red reset button.
Blocked exhaust pipe.
Clean the exhaust pipe.
Blocked fuel filter.
Clean the fuel filter.
Defective ignition, print plate or
Contact your dealer.
fuel pump.
EE6
Flame goes out imme-
Air bubble in fuel pipe.
Press the red reset button.
diately after ignition.
No fuel.
Check the fuel meter on the tank,
top up if necessary.
Overheating safety feature is
Clean the protective cap on the ven-
activated.
tilator, remove dust and obstacles.
Defective flame sensor.
Contact your dealer.
Fuel supply is blocked.
Contact your dealer.
Pressure on fuel supply is incorrect.
Adjust the pressure on the fuel sup-
ply to a maximum of 2.5 PSI
(± 0.17 bar).
Float mechanism does not work.
Contact your dealer.
Poor/noisy combustion.
Soot formation in the exhaust pipe.
Remove the soot from the exhaust
pipe.
Burner ring is fitted incorrectly.
Contact your dealer.
Altitude above sea level too great.
Contact your dealer.
Excessive wind pressure in the
Place a windbreaker.
exhaust pipe.
Odours.
Leaking exhaust pipe.
Check/repair the exhaust pipe
(Pay special attention to all the
connections)
Fuel leak.
Check/repair all the connections in
the fuel supply pipe.
Poor sealing in/at the burner
Contact your dealer.
chamber.
EE8
Defective blower motor
Contact your dealer.
EE10
Heater will not switch off. Too much fuel in the burner.
Contact your dealer.
Hi
The room temperature is
Check that the room temperature
higher than 35º C.
sensor is in the correct position.
Lo
The room temperature is
Check that the room temperature
lower than –10º C.
sensor is in the correct position.
Warning: Stop using the heater if error EE10 occurs. Only restart the heater when this problem has been resolved.
Note: If you have checked/remedied all possible causes of the problem and the heater will not start after 3