ARABELLA

2

6

3

4

>

1

=

gEBRAUchsAnWEisUng

BRUgsAnVisning

MAnUEL D’UTiLisATiOn

OPERATing MAnUAL

isTRUziOni D’UsO

gEBRUiKsAAnWiJzing

BRUKsAnVisning

2

18

34

50

66

82

98

man_Arabella ('09).indd   1

02-09-2009   08:49:26

Summary of Contents for ARBELLA

Page 1: ...ARABELLA 2 6 3 4 1 gebRaUchsanWeisUng BRUGSANVISNING MANUEL D UTILISATION OPERATING MANUAL istRUzioni d Uso GEBRUIKSAANWIJZING Bruksanvisning 2 18 34 50 66 82 98...

Page 2: ...t flue chimney not included in deli very Exhaust flue damper not included in deli very glass cleaning air inlet Inspection win dow fire hearth Door gasket Handle Ash grid shaker Primary air inlet cont...

Page 3: ...of comfort and pleasure In order to ensure the maximum life span and safe use of your Zibro heating pro duct Please carefully read this manual first and store it for future reference On behalf of the...

Page 4: ...above the normal ventilation requirement for the room Always have a fresh air inlet to the room with a section of at least a quarter of the section of the exhaust flue with a minimum of 100 cm2 It mig...

Page 5: ...y following the local legislation and or your insurance prescription If no local legislation and or insurance prescription make sure that at least twice per year first time at the begin ning of the he...

Page 6: ...gency Never use water to stop the fire Use a CO2 carbon dioxide fire extinguisher or call the fire brigade In case of chimney fire also close the chim ney damper if mounted A 2 Normal stop of the stov...

Page 7: ...n unpleasant though non harmful odour will be produced the above described procedure must be followed for at least the first four times the stove is used D nORMAL OPERATiOn OF ThE sTOVE to start the s...

Page 8: ...fill the stove with a single layer of wood close the charging door keep the charging door open for shortest possible time Avoid operating the stove at windless weather and foggy misty weather At these...

Page 9: ...d work scraps with glues and or solvents waste wood in general cardboard for start up purposes a minimum of paper may be used only during the starting phase painted or impregnated wood bonded wood suc...

Page 10: ...ing the fire bed walls Twice per year first time at beginning of season checking stone behind front charging door Twice per year first time at beginning of season Clean the room air circulation filter...

Page 11: ...first time at begin ning of season Cleaning sweeping the chimney flue system twice per season first time at begin ning of season replacing parts not mentioned in this manual upon signalling damages c...

Page 12: ...ch can break with high temperature shocks or when it drops on the floor Have it replaced by a by Zibro authorized technician if needed Only use original Zibro spare parts E 3 7 The stone behind the fr...

Page 13: ...h draught Primary air inlet to minimum Condensation forms Chimney flue section is too large Reduce the chimney flue section using thermally insulated pipes needs to be done by specialised heating engi...

Page 14: ...actions not in compli ance with the directions for use as indicated in this manual neglect and the use of an incorrect type of fuel The use of incorrect fuel can even be dangerous 7 Transportation cos...

Page 15: ...advice Model Arabella Type of stove Wood Capacity W 9000 Electrical power consumption W 20 Power supply V Hz PH 230 50 1 Thermal efficiency 74 5 CO level at 13 O2 0 31 For rooms up to m3 270 Exhaust...

Page 16: ...its design and type Product Description Roomheaters fired by Solid fuel Brand of Product Zibro Reference of Product Arabella Applicable EC Directives EC Construction Products directive 89 106 EEC Appl...

Page 17: ...65 4...

Page 18: ...l 45 70 205 701 fax 45 70 208 701 email appliance appliance group com FIN 4 UNITED KINGDOM Scott Brothers Ltd 1 Whiteside Station Road Holmes Chapel Cheshire CW4 8AA UK tel 44 0 1477 539 500 fax 44 0...

Reviews: