.
12
8965, 8968, 8975, and 8985 Access Cards
8900-A2-ZZ40-50
Refer to
Connector Pin Assignments
in the
Model 8965, 8968, 8975, and 8985
Access Cards User’s Guide
for pinouts of the access card connectors.
To connect each receptacle of a 48-port access card to an MDF or POTS
splitter:
1
Replace the longer captive screw on your cable connector with the #4-40
Phillips pan-head screw shipped in a plastic bag with the BLC.
2
Install the locking pivot bracket onto the cable end of the connector using
the captive screw, as illustrated below.
3
Insert the bottom edge of the locking pivot bracket into the hook next to
the receptacle.
4
Align the two connectors and press the cable connector onto the
receptacle.
5
Tighten the captive screw on the top of the cable's connector.
Locking Pivot
Bracket
Captive #4-40 Phillips-Head Screw
(Part of Locking Pivot Bracket)
Customer-Supplied
Cable with Connector
Replace with a shorter
Captive Screw provided
with the Pivot Bracket
99-16162a-02
Locking Pivot
Bracket
Locking Pivot
Bracket
Receptacle on Card
04-17513