08
09
www.zj-woq.cn
STOP THE MACHINE
■
1. Pull the throttle to low speed position
■
2. Close the outlet valve
■
3. Turn on the main switch to “off”
■
4. Close the oil tank switch
■
5. Open the drain valve, make sure all water is out of the pump, then close it.
ATTENTIONS DURING OPERATIONS
To avoid improper operation of fire pumps, read and comply with the following attentions
WARNING: DO NOT
run the engine in an enclosed area as poisonous gases are given off, which can cause
injury.
WARNING: DO NOT
touch pulley, belt or other moving parts which can lead to serious injury, when the
engine is running
WARNING: DO NOT
touch the spark plug ignition wires, which are with high voltage, and can lead to
serious injury.
WARNING: DO NOT
touch the exhaust system and muffler when the engine is running or stopped within 10
minutes, as they are very hot and can cause injury.
CAUTION
01. DO NOT OPERATE
the fire pump close to flammable materials or structures (distance should be more
than 3m)
02. DO NOT OPERATE
the fire pumps on dry grass ground. The exhaust system is very hot and easy to light
it. Clean it if needed.
03.
Do not bend or squeeze the suction hose during working, which may cause injury).
04. DO NOT START
the engine when the outlet valve is open
05.
Engine must be in idle running when open or close the outlet valve.
06. MUST NOTIFY
the nozzle operator if the engine speed or the position of the outlet changes, which cause
injury.
07.
Nozzle operator should adapt shoulder leather hose to control it, it need 2 persons to control it if too much
pressure
08.
Do not spray to people directly at any case.
09.
Do not look into the hose when open the outlet at any case.
Security, guaranteed with my presence!
(
Pic 7
)
5. Use throttle to adjust water outflow and pressure
SUCTION AND SPAY OUT
■
1. After starting the engine, pull down the vacuum pump handle. (As Pic 6)
■
2. Check the water comes out from the drainage pipe or not, the pressure gauge point to the positive range.
■
3. Return the vacuum pump handle to original position
NOTICE:
* No water come out after 30seconds; check the relevant items on “Fault handling table”
* Water should not be lower than 9m, otherwise the pump could not suction.
* Put the suction pipe on uneven or rough place, air will accumulate. If water do not spray out fluently after
open the outlet valve. Please re-operate the vacuum pump. If suction hose accumulate air, open the outlet
valve; run the vacuum pump every 3-5seconds, till the water flow fluently.
* Inspect the height of the water frequently when spraying. The hose filter should be 30cm below the water. If
there is much sediment in the water, use dense mats or meshes to keep it away.
■
4. Open the outlet valve. (As Pic 7)
* Notify the nozzle operator before open the outlet valve.
* The outlet could be rotated about 90 degrees, stop the engine and open the valve when rotating
NOTICE:
Suction hose will accumulate air if some parts is higher the outlet. Water does not flow to the
outlet when the outlet valve is open; Reopen the vacuum if such thing happens.