Trip current

0-1000A

The  BMS16  will  automatically  shut  down  the 
battery  pack  if  current  exceeds  this  threshold 
(for  over  1  second  continuously).  Note:  This 
should not replace a physical fuse, but can be 
used as a “first line of defence”.

This  is  considered  a  serious  error  which  will 
require the device to be power cycled to reset.

Thermal limit

0-100C

The  BMS  can  automatically  shut  down  the 
battery  pack  (both  charge  and  load  output 
relays)  if  the  measured  temperature  exceeds 
this  programmed  threshold.  This  error  will 
automatically reset once temperature drops by 
at least 10 degrees below threshold.

Min voltage

1.00-5.00V

The  minimum  voltage  any  single  cell  should 
be allowed to reach. If any cell goes below this 
threshold (minus any hysteresis), the LV output 
relay will go open circuit.

Max voltage

1.00-5.00V

The  maximum  voltage  any  single  cell  should 
be allowed to reach. If any cell goes above this 
threshold (plus hysteresis), the HV output relay 
will go open circuit.

BMS hysteresis

0-1.00V

This  settings  provides  some  hysteresis  on 
voltage  thresholds,  such  that  charge  and  load 
relays are not switched on and off too rapidly. 
For example, with a 0.2V hysteresis, the LV relay 
will be disabled when a cell goes 0.2V below 
the Min Voltage threshold, and re-enabled once 
the cell recovers to 0.2V above Min Voltage.

Shunt voltage

1.00-5.00V

The voltage threshold where shunt balancing will 
occur. Balancing should only be performed on 
cells which are higher than average, so typically 
set this to the average maximum charge voltage 
of each cell (i.e max charge voltage divided by 
number of cells).

Shunt size

100A / 200A / 

500A

This selects the size of current shunt attached to 
the BMS16 (for 75mV shunts). Note that if using 
an external CAN bus shunt interface, this setting 
is  ignored  as  the  external  device  is  separately 
programmed with its shunt size.

BMS Power Consumption Protection

An inherent problem with any BMS which powers itself from the cells it is monitoring is that 
the BMS can slowly discharge the cells, which can eventually flatten cells – particularly if 
powering contactors or monitors, and no charging source is present for an extended period. 
To prevent possible damage, the BMS16 is able to switch of its own power supply if any cells 
get critically low (under 2.0V). If your BMS has turned off due to a critically low cell, simply 
attach a charging source to the batteries then press the power button to re-enable the BMS.

Tech Support and Warranty Information

All  ZEVA  products  are  covered  by  a  12  month  warranty  against  manufacturing  faults  or 
failures  under  normal  operating  conditions. The  warranty  does  not  cover  misuse  of  the 
product, including but not limited to: excessive voltage or reversed polarity on terminals, 
short circuits on outputs, opening of housings and/or modification of internal electronics, 
severe impact damage, submersion in water.

We have taken great care to design a safe and reliable product, but faults can happen. If 
you believe your product has a fault, please contact us via our website to discuss. If it is 
determined that a hardware fault is the likely cause, we will provide an RMA number and 
return address to proceed with repairs.