33
Peak power(Back-up)(W)
1.5x Pnom, 10sec
1.5x Pnom, 10sec
Max. AC current(A)
20
16
Nominal AC output
50/60Hz; 230Vac
AC output range
45~55Hz/55~65Hz; 180~270Vac
AC output (Back-up)
230Vac ±2%, 50Hz ±0.2%, THDv<3% (linear load)
THDi
<1.5%
Power factor
0.9 leading~0.9 lagging
Grid connection
Single phase
Efficiency
Max. efficiency
97.6%
97.6%
Euro efficiency
97.0%
97.0%
MPPT adaptation efficiency
>99.5%
Protection
Residual current
monitoring unit
Integrated
Anti-islanding
protection
Integrated
DC switch(PV)
Integrated
AC over current
protection
Integrated
Insulation monitoring
Integrated
Certifications & Standards
Grid regulation
VDE4105, VDE 0126-1-1+A1, G83/2, G59/2, AS4777.2/.3,
IEC62109-2
Safety
IEC62109-1&-2, AS3100, IEC62040-1
EMC
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4,
EN61000-3-11, EN61000-3-12
General Data
Dimensions (WxHxD)
516*440*184mm
Weight (kg)
30
28
Mounting
Wall bracket
Ambient temperature
range
-25~60°C
(
>45°C de-rating
)
Relative humidity
0~95%
Max. operating
altitude
2000m
Protection degree
IP65
Topology
Transformerless