b.  Safety Parameters 

Setting of safety parameters: 

Click

Setting

----

“Safety Parameters”

 

 

 

Summary of Contents for Z10I13KDT

Page 1: ...User Manual V3 2 User Manual Installation Operation Z10I13KDT Z10I17KDT Z10I20KDT Zeus Appollo Solar...

Page 2: ......

Page 3: ...Appearance 112 4 3 Product Identification 133 4 4 Further Information 14 5 Installation 156 5 1 Safety 156 5 2 Dimensions and Weight 156 5 3 Mounting Instructions 157 5 4 Safety Clearance 178 5 5 Moun...

Page 4: ...2 7 2 5 Error 44 7 2 6 Update 45 7 3 State Information 46 8 Troubleshooting 48 9 Warranty 50 10 Abbreviation 52 11 Contact 53...

Page 5: ...vailable at all times in case of emergency 1 3 Symbols Used CAUTION CAUTION indicates a hazardous condition which if not avoided can result in minor or moderate injury or moderate injury WARNING WARNI...

Page 6: ...ending to install or uninstall the Z10 Series Grid tied Solar Inverter Installation must be suitable for the on site conditions and comply with local regulations and technical rules NOTICE Qualified p...

Page 7: ...ding the modification of product functionality of any kind will affect the extent of the warranty Such actions may result in Zeus Appollo Solar not accepting any responsibility for that warranty DANGE...

Page 8: ...shortly after operation Risk of damage due to modi cations Never modify or manipulate the inverter or other components of the system NOTICE Public utility only The PV inverter is designed to feed AC...

Page 9: ...erter will generate heat during operation DO NOT touch aluminum housing during operation An error has occurred Please go to Chapter 8 Trouble Shooting to remedy the error This device SHALL NOT be disp...

Page 10: ...8 3 Product Information 3 1 Overview Industrial Layout Excellent Heat Elimination Effective Shield For DC AC Communication Connections...

Page 11: ...ection Level IP65 which will ensure that the unit will perform correctly in severe outdoor conditions Complete safety protection with an integrated DC switch Flexible input and output connections whic...

Page 12: ...Feed in Starting Power 60W 60W 60W Night time Power Consumption 1W 1W 1W Standby Consumption 12W 12W 12W AC Connection Type Plug in connector Plug in connector Plug in connector Type Z10I13KDT Z10I17...

Page 13: ...Communication RS232 USB Standard Warranty 5 Years 10 years optional The AC voltage and frequency range may vary depending on the specific country grid 4 Packing checklist 4 1 Assembly parts After you...

Page 14: ...1 Wall mounting bracket C 1 User manual D 4 Screws ST6x50 E 4 Expansion tubes F 1 AC cover G 6 DC connectors 6 x positive 6 x negative H 1 Ground nut M6 I 5 Cord end terminals J 4 Screws M4X12 4 2 Pro...

Page 15: ...13 A LED light Green RUN B LED light Red FAULT C LED light Yellow COM D left choice E Right choice F up choice G down choice H Ok identify key Bottom Left and right A H B F G E D C...

Page 16: ...iption A DC switch B Plug connectors for DC input C RS232 interface D RS485 interface E Earthing F Ethernet interface G USB interface H Terminal for grid connection AC output I Update and reset switch...

Page 17: ...on the side name plate The name plate is located on the middle part of the right hand side of the inverter housing The following figure is an example of the side name plate on the Z10I17KDT 4 4 Furth...

Page 18: ...n of the inverter An Installation under the direct sun is not recommended The installation site MUST have adequate ventilation DANGER DANGER to life due to potential fire or electricity shock DO NOT i...

Page 19: ...ure that the wall selected for installation is strong enough for the mounting screws and can bear the weight of the inverter Ensure the device is properly fixed to the wall It is not recommended that...

Page 20: ...g minimum clearances to walls other devices or objects to guarantee sufficient heat dissipation and enough space for pulling the electronic solar switch handle Direction Minimum clearance Above 20 cm...

Page 21: ...19 5 5 Mounting Procedure 1 Mark 4 positions of the drill holes on the wall according to the paper installation position guide packed in the carton box...

Page 22: ...ext insert the 4 screws through the mounting holes in the bracket and then tighten the screws into the expansion tubes 3 Check the 4 holes at the rear of the inverter then lift the inverter carefully...

Page 23: ...21 4 Please carefully check the accessories in the original carton to make sure every necessary part is used and nothing is missing during installation...

Page 24: ...R DANGER to life due to potential fire or electricity shock When the inverter powered up comply with all applicable national regulations and legislation concerning accidents prevention This inverter w...

Page 25: ...nterface H Terminal for grid connection AC output 6 3 DC Side Connection NOTICE The DC Switch Optional may be integrated or external to Inverter and it can be used to connect or disconnect the DC sour...

Page 26: ...21200W 22 22A Connection procedure by MC4 Connect the PV modules and inverter using MC4 connectors below Connect the positive and negative terminals from the PV modules to positive terminals and negat...

Page 27: ...when the contact cable assembly is seated correctly 6 Wrest the cap by using a torque of 2 6 2 9NM 7 After wresting the cap tightly align the 2 half connectors and mate them together by hand until a...

Page 28: ...the operating procedure is similar as that of a MC4 connector 6 4 AC side connection Connection Procedure 1 Strip the cable 12mm NOTICE DC Switch Optional may be integrated or external to Inverter and...

Page 29: ...below picture 3 Insert the finished 5 lines of cable into the AC cover assembly with the following sequence Open the plastic cover use a slot type screwdriver to press the shrapnel in the indicated p...

Page 30: ...28 Cover the assembly tightly screw and then screw in the cable gland...

Page 31: ...ter as shown in the following figure The function is as below Object Description Function C RS232 interface Update the Software Version of the inverter D RS485 interface Connect with PMB F Ethernet in...

Page 32: ...d Operation e g normal Current operation condition E today The energy generated today in kilo watt hours kWh E total The energy generated since starting up the inverter kWh The LCD panel is integrated...

Page 33: ...g instrument for current voltage or power consumption A slight deviation of a few percent points is inherent to the system the results from the inverter cannot be used for grid balance calculations An...

Page 34: ...32 7 2 1 Curve a P Now Draw curve of current power Click Curve P Now...

Page 35: ...33 b P Day Draw curve of one day s power Click Curve P Day...

Page 36: ...34 c E Month Show one month s generated energy Click Curve E Month...

Page 37: ...35 d E Year Draw curve of one year s generated energy Click Curve E Year...

Page 38: ...36 e E Total Draw curve of every year s generated energy Click Curve E Total...

Page 39: ...37 7 2 2 Parameters a AC Parameters Show AC parameter Click Actual Value AC Actual Value...

Page 40: ...38 b DC Parameters Show DC parameter including following items Vpv 1 2 Ipv 1 2 Click Actual Value DC Actual Value...

Page 41: ...39 7 2 3 Tools Options a Language and Time Setting of language time Click Setting Language and Time...

Page 42: ...40 b Safety Parameters Setting of safety parameters Click Setting Safety Parameters...

Page 43: ...41 c Clear Data Clear Log...

Page 44: ...42 Click Setting Clear Data...

Page 45: ...43 7 2 4 Information Device Info Type of inverter 13K 17K 20K Vision number serial number Click Information Device Info...

Page 46: ...44 7 2 5 Error Error Info Show Error information Click Error Error Info...

Page 47: ...45 7 2 6 Update...

Page 48: ...Communication Fails between M S EEPROM R W Fail EEPROM R W Fail Relay Check Fail Relay Check Fail DC Injection High DC Injection High The result of Auto Test Function is fail The result of Auto Test F...

Page 49: ...onsistent Fault Vac differs for M S Consistent Fault Fac differs for M S Consistent Fault Fac differs for M S Ground I differs for M S Ground I differs for M S DC inj differs for M S DC inj differs fo...

Page 50: ...ange 1 Wait for a moment if the grid returns to normal PV Inverter automatically restarts 2 Make sure grid voltage and frequency meet the specifications Utility Loss 1 Grid is not connected 2 Check gr...

Page 51: ...from the input restart the inverter AC Relay Check Fail 1 Disconnect ALL PV or PV 2 Wait for a few seconds 3 After the LCD switches off reconnect and check again 4 If the problems remain please call...

Page 52: ...vestment Australia Pty Ltd hereinafter referred to as Zeus Appollo Solar 2 If the inverter malfunctions or becomes inoperative due to a defect in workmanship or material under normal operation as spec...

Page 53: ...s warranty 1 Product warranty period is expired excluding additional agreements of warranty extension 2 Faults or damages due to operations against Zeus Appollo Solar instructions installation and mai...

Page 54: ...ac Voltage at the AC side Vmpp Voltage at the Maximum Power Point Impp Amperage at Maximum Power Point AC Alternating Current Form of electricity supplied by Utility Company DC Direct Current Form of...

Page 55: ...ite www zeusappollo com Perth Office 1 87 President Street Welshpool WA 6106 Phone 08 6555 6518 Fax 08 9470 4103 Email sales zeusappollosolar com au Brisbane Office 32 Crockford Street Banyo QLD 4014...

Reviews: