Common Control Equipment Installation
102
Wiring to the Service Ports
The CCE provides several 9-pin “D-type” female receptacles, J10 – J13, for connecting to
service ports. The connectors are located on the top right-hand side of the back of the
console cardcage (see
).
Table 41: Logger, Modem, and RSM Serial Signals
Table 42: Clock Serial Signals
The baud rate for each port is selectable using the Data Rate switches on the front panel of
the STC card. The protocol for each port is 8 data bits, 1 stop bit, and no parity.
Pin
Signal Name
Signal Function
1
No Connection
2
Rx Data
Receive Data signal from external device
3
Tx Data
Transmit Data signal to external device
4
DTR
Pulled to plus voltage
5
Signal Ground
Ground to external device
6
No Connection
7
RTS
Request-To-Send.
8
CTS
Clear-To-Send
9
No Connection
Pin
Signal Name
Signal Function
1
No Connection
2
Rx Data
Connect to TDATA on NETCLOCK
(Pin 5 of Remote Output)
3
No Connection
4
No Connection
5
Signal Ground
Connect to Ground on NETCLOCK
(Pin 9 at Remote Output)
6
No Connection
7
No Connection
8
No Connection
9
No Connection
Summary of Contents for 4000 Series
Page 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Page 6: ...6 025 9533Y...
Page 28: ...Introduction 28 025 9533Y...
Page 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Page 110: ...Common Control Equipment Installation 110 025 9533Y...
Page 172: ...Console Installation 172 025 9533Y...
Page 192: ...Audio Level Adjustments 192 025 9533Y...
Page 230: ...Accessory Installation 230 025 9533Y...
Page 236: ...Console ANI Programming 236 025 9533Y...
Page 339: ...339 RSMP Operation Figure 99 Main Screen...
Page 350: ...Radio System Management Program 350 025 9533Y...
Page 362: ...Appendix B Troubleshooting 362 025 9533Y...
Page 418: ...Index 418 025 9533Y...