background image

10     USE AND CARE

Operating the TDS Meter

ALWAYS CHANGE FILTER 
CARTRIDGE WHEN TDS 
METER READS “006”

1.  Remove the cap from the end of the 

TDS Meter.

2.  Push the “ON/OFF” button. The meter 

should read “000”.

3.  Place the end of the meter in one inch 

of water. Do not fully submerge the TDS 
Meter; this may short circuit the battery.

4.  Wait a few seconds for the reading to 

stabilize. To keep the reading on the 
display, press the “HOLD” button so 
that you can read the number when you 
remove the meter from the water.

5. Do not use in hot water.

CHANGING THE TDS METER BATTERIES (two 1.5v button cell)

1. Use a fi ngernail to remove the cap at the end that says “TDS”.

2. Replace the old batteries with two new batteries.

3. Replace the cap.

UNDERSTANDING THE TDS METER

 

The TDS meter helps you put a number on what your taste buds are already telling you 
about what’s in your water. It measures for the things in water that can give it a taste. 
The higher the reading on the water, the more substances dissolved in your water.

For a more scientifi c explanation, it is showing you the total number of detectable 
dissolved solids in water. With the push of a button, the electrodes in the bottom 
of the tester measure the amount of ions in the water and convert that amount 
to a number that displays on the screen. The number represents the amounts of 
detectable dissolved solids in parts per million that exist in your water sample.

The meter is primarily used to indicate ZeroWater

®

 fi lter replacement at 006. It may 

also be used as a simple method to compare water quality by displaying the Total of 
the Dissolved Solids (TDS) in parts per million only. The meter does not specify what 
substances comprise the Total. The meter should not be used to assess the safety or 
purity of water, which should only be undertaken by a qualifi ed laboratory.

HO

LD

ON/

OF

F

ximum

mersion
Level

old

/Off

BATTERY
COMPARTMENT

HOLD

ON/OFF

MAXIMUM
IMMERSION
LEVEL

Summary of Contents for Filter Bottle

Page 1: ...USE AND CARE 1 OWNER S MANUAL FILTER BOTTLE FOR STANDARD COOLERS MEASURE AND TASTE THE DIFFERENCE 0 0 0...

Page 2: ...1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 24 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2...

Page 3: ...phone call to our trained professionals SAFETY PRECAUTIONS Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithout proper disinfection before or after the system Individuals requiring...

Page 4: ...will cause your water to spill DIRECTIONS FOR REMOVING THE SPLASH GUARD If you look into the reservoir you ll see the splash guard with a spike used to pierce a hole in the cap of bulk water containe...

Page 5: ...it www zerowater com recycling to download a form Place your used filter into a sealable plastic bag and be sure it is sealed tightly Place your used filters and your completed form in a well packed b...

Page 6: ...4 USE AND CARE LID UPPER CHAMBER FILTER CARTRIDGE LOWER CHAMBER FLOAT VALVE WITH SOFT WASHER LOWER CHAMBER DIVIDER RIM MAXIMUM WATER LEVEL FILTER O RING...

Page 7: ...apping the lower chamber If assembled upside down there will be leakage Be sure it fits tightly on the lower chamber see ZeroWater Filter Bottle components on page 4 2 Screw float valve tightly into h...

Page 8: ...nd the drain plug in the back of the cooler Using a cooler without water in it when plugged in can cause it to smoke and break Make sure you secure the drain plug when you are finished draining the co...

Page 9: ...t doesn t read 000 flush the water out and pour new water through 6 Do not over fill The first time you fill your Filter Bottle it will take extra water to fill the cooler reservoir When water in the...

Page 10: ...ove fine particles It is essential to change the filters with a reading of 006 on the included TDS meter in order for the product to continue to perform as represented The longevity of the filter may...

Page 11: ...nd the problem is an unclean cooler reservoir or spigot Try cleaningthecoolerreservoirandspigotagain The TDS Meter does not turn on Remember that you should not dip the meter too far into the water as...

Page 12: ...the things in water that can give it a taste The higher the reading on the water the more substances dissolved in your water For a more scientific explanation it is showing you the total number of de...

Page 13: ...l then give you instructions on how to send back the cartridges to be tested by our laboratory Depending on whether or not the lab determines the cartridges to be defective they will either be replace...

Page 14: ...www zerowater com 1 800 503 2939 2008 Zero Technologies LLC Bensalem PA 19020...

Reviews: